GD3126A (GD3126B) Olùdánwò Resistance Insulation 5kV/10TΩ (10kV/20TΩ)
GD3126A (GD3126B) Idanwo Resistance Insulation jẹ lilo pupọ ni itọju ohun elo itanna ni ile-iṣẹ iyipada, ọgbin agbara, ati bẹbẹ lọ O dara fun gbigbe wiwọn ti idabobo idabobo (IR), ipin gbigba (DAR), atọka polarization (PI), jijo lọwọlọwọ (Ix) ati agbara gbigba (Cx) ti gbogbo iru ohun elo foliteji giga, pẹlu switchgear, awọn oluyipada, awọn reactors, capacitors, mọto, awọn olupilẹṣẹ ati awọn kebulu, ati bẹbẹ lọ.
●Gba iṣakoso microcomputer, iṣiṣẹ akojọ aṣayan ati ifihan matrix aami iboju iboju LCD nla pẹlu iṣẹ iduroṣinṣin.
●Agbara kikọlu ti o lagbara, o dara fun wiwọn ni agbegbe kikọlu eletiriki to lagbara.
●Agbara nla, le pade awọn ibeere ti foliteji giga, resistance giga, idanwo fifuye agbara nla.
●Pẹlu mọnamọna, ẹri-ọrinrin ati ilana ẹri eruku, ni ibamu si agbegbe iṣẹ lile.
●Ọrẹ olumulo, ṣafihan awọn abajade deede ati awọn aṣa iyipada data.
●Iṣẹ aabo pipe, ni anfani lati koju ipa ti Circuit kukuru ati foliteji aloku agbara wiwọn.
●5 foliteji o wu awọn igbesẹ ti 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
●6 foliteji o wu awọn igbesẹ ti 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV.Foliteji giga ti igbesẹ kọọkan jẹ adijositabulu nigbagbogbo lati odo.
●O wu ga foliteji tun le nigbagbogbo ni titunse.
●Iwọn aifọwọyi ti R15, R60, R600, iṣiro aifọwọyi ti ipin gbigba, itọka polarization.
●Iwọn wiwọn resistance ti o pọju jẹ 0 ~ 10TΩ (0 ~ 20TΩ), ibiti o yipada laifọwọyi.
●Wiwọn aifọwọyi ti iwọn otutu ibaramu, ọriniinitutu afẹfẹ ati akoko idanwo.
●Ṣe afihan akoko idanwo, awọn imọran buzz ni gbogbo iṣẹju-aaya 15, awọn iṣẹju 5 laisi iṣẹ yoo tọ tiipa.
●Fi foliteji giga silẹ laifọwọyi lẹhin wiwọn ti pari, akoko idasilẹ ko ju awọn aaya 30 lọ.
●Ibi ipamọ ti awọn ẹgbẹ 60 ti awọn abajade wiwọn, aibikita fun ọdun 20..
●Pẹlu RS232 ni wiwo tẹlentẹle, ni anfani lati ṣe ibasọrọ data pẹlu kọnputa.
●Pẹlu itẹwe ita, le tẹ awọn abajade wiwọn sita.(aṣayan)
●Foliteji ti ayẹwo idiyele jẹ afihan ṣaaju idanwo ati pe o ni awọn amọran ti o yẹ.
●Akoko idanwo tito tẹlẹ, da wiwọn duro laifọwọyi;
●Ni anfani lati ṣe awari jijo lọwọlọwọ Ix ati agbara gbigba Cx.
Ti won won foliteji awọn igbesẹ ti | GD3126A (5kV) GD3126B (10kV) | ||||||
250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV | |||||||
Aṣiṣe foliteji ti o wu jade | ± 5% | ||||||
Resistance ibiti o | Oke iye to | 500GΩ~10TΩ | |||||
Iwọn isalẹ | 0.1MΩ | ||||||
Yiye kilasi | 5.0 kilasi | ||||||
Ga foliteji àpapọ aṣiṣe | ± ( 5% • Ux + 1 oni-nọmba ) | ||||||
Yiyọ lọwọlọwọ Ix iwọn wiwọn & aṣiṣe | 0.1nA~9.9mA 5% | ||||||
Absorption capacitance Cx iwọn iwọn & aṣiṣe | 0.1pF ~ 99ɥF 5% | ||||||
Aṣiṣe wiwọn iwọn otutu | ± 0.5 ℃ | ||||||
Aṣiṣe wiwọn ọriniinitutu | ± 2% RH | ||||||
Kukuru Circuit lọwọlọwọ | <6mA | ||||||
Foliteji ripple | <3% | ||||||
Akoko idanwo | Titi di awọn iṣẹju 99 | ||||||
Idaabobo idabobo | > 500 MΩ (laarin okun waya idanwo ati ọran) | ||||||
Koju foliteji | AC10.0kV 50Hz 1min (laarin okun waya idanwo ati ọran) | ||||||
Ibi ti ina elekitiriki ti nwa | 12V batiri litiumu | ||||||
Akoko iṣẹ batiri lẹhin gbigba agbara kan | 30days 10times DAR & 5times PI idanwo fun ọjọ kan | ||||||
Ṣiṣẹ otutu ati ọriniinitutu | 0℃ ~ + 40℃ < 85% RH | ||||||
Ibi ipamọ otutu ati ọriniinitutu | -20℃ ~ + 50℃ <90%RH | ||||||
Ibi ti ina elekitiriki ti nwa | 220V AC 50Hz | ||||||
Iwọn (mm) | 325 (L)*250(W)*130(H) | ||||||
Iwọn | 3.7kg | ||||||
Aṣiṣe wiwọn resistance | |||||||
Awọn igbesẹ foliteji | 250 V | 500 V | 1.0 kV | 2.5kV | 5.0 kV | 10KV | |
± ( 3%·Rx + 1d) | 1GΩ | 2GΩ | 4GΩ | 10GΩ | 20GΩ | 40GΩ | |
±( 5%·Rx + 1d) | 10GΩ | 20GΩ | 40GΩ | 0.1TΩ | 0.2TΩ | 0.4TΩ | |
± ( 10%·Rx + 2d) | 100GΩ | 200GΩ | 0.4TΩ | 1TΩ | 2 TΩ | 4TΩ | |
± (25%·Rx + 2d) | 500GΩ | 1TΩ | 2TΩ | 5TΩ | 10TΩ | 20TΩ |
Idanwo resistance idabobo | 1 ṣeto |
Ṣe idanwo okun asopọ fun L ebute (pupa) | 1 root (1 nkan) |
Ṣe idanwo okun asopọ fun G ebute (Awọ ewe) | 1 root (1 nkan) |
Ṣe idanwo okun asopọ fun E ebute (dudu) | 1 root (1 nkan) |
3Apower ohun ti nmu badọgba (Fun ipese agbara itẹwe ati gbigba agbara irinse) | 1 piece (1 nkan) |
RS232 Serial ibaraẹnisọrọ ila | 1 root (1 nkan) |
olumulo's itọsọna | Ẹda 1 (ege 1) |
Iroyin igbeyewo | Ẹda 1 (ege 1) |
1. L ebute oko 2. G ebute oko 3. E ebute oko 4. LCD iboju.
5. Buzzer 6. Iwọn otutu & sensọ ọriniinitutu 7. Bọtini ESC 8. Bọtini UP
9. Kokoro itansan 10. Bọtini isalẹ 11. Bọtini O dara12. Ga foliteji Siṣàtúnṣe iwọn koko
13. RS232 ni wiwo 14. Power yipada15. Iho gbigba agbara