Awọn Eto Idanwo Foliteji giga AC fun GIS
●Amunawa
●Eto GIS
●SF6 yipada
●Awọn okun
●Bushing
●Insulator
●CT/PT
●Miiran capacitive awọn ẹrọ
●Iwọn otutu kekere ga soke ni fifuye ti o ni iwọn.Gbẹ tabi Epo iru reactors, ga darí agbara, ti o dara idabobo, dara ati ki o gbẹkẹle.
●Agbara adijositabulu ti orisun iṣakoso igbohunsafẹfẹ.Idaabobo to lagbara, iduroṣinṣin to dara.Pẹlu ipo iṣẹ lọpọlọpọ, rọrun lati ṣiṣẹ.
●Pẹlu 220V tabi 380V agbara alakoso ẹyọkan, rọrun fun orisun agbara aaye.
●Iṣeto ni irọrun.Awọn reactors oriṣi oriṣiriṣi fun aṣayan, pade awọn ibeere ohun elo idanwo oriṣiriṣi.Multifunctional, iye owo to munadoko.
●Foliteji abajade ti a ṣe iwọn: da lori oriṣiriṣi awọn nkan idanwo.
●Igbohunsafẹfẹ ijade: 20-300Hz.
●Igbi igbi: igbi omi mimọ, THD <1.0%.
●O pọju.agbara: 1000kVA ati isalẹ.
●Yiyika Iṣẹ: Akoko iṣẹ tẹsiwaju 15mins ni akoko kan ni iṣelọpọ agbara ni kikun.(tabi ibeere alabara.)
●Ifamọ atunṣe atunṣe igbohunsafẹfẹ: 0.1Hz, aiṣedeede <0.05%.
●Ipese Agbara: 380/220V ± 15%/50Hz ± 5%.
GDTF-108/108 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-108 |
Agbara (kVA) | 108 |
Ohun elo dopin | 31500kVA tabi isalẹ |
35kV agbara transformer | |
35kV Circuit fifọ ati ọkọ akero, insulators | |
10kV (300 mm²) okun 2000m | |
35k V (300 mm²) okun 500m | |
Awọn atunto akọkọ | 5kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
5kVA Moriwu transformer 1 ṣeto | |
Reactors 27kV / 1A 4sets | |
Capacitive pin 100kV | |
GDTF-216/216 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-216 |
Agbara (kVA) | 216 |
Ohun elo dopin | 110kV Circuit fifọ ati ọkọ akero |
110kV GIS | |
35kV(300 mm²) okun 1500m | |
10kV(300 mm²) okun 3km | |
110kV kikun idabobo Amunawa | |
Awọn atunto akọkọ | 10kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
10kVA Moriwu transformer 1 ṣeto | |
Reactors 54kV/1A 4sets | |
Capacitive pin 200kV | |
GDTF-270/270 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-270 |
Agbara (kVA) | 270 |
Ohun elo dopin | 110kV GIS ati transformer |
110kV GIS ati transformer | |
35kV (300 mm²) okun 2km | |
Awọn atunto akọkọ | 15kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
15kVA Moriwu transformer 1 ṣeto | |
Reactors 54kV/1A 5sets | |
Capacitive pin 300kV | |
GDTF-400/400 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-400 |
Agbara (kVA) | 400 |
Ohun elo dopin | 220kV GIS ati transformer |
10kV (300 mm²) okun 4km | |
35kV (300 mm²) okun 1km | |
Awọn atunto akọkọ | 20kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
20kVA Moriwu transformer 1 ṣeto | |
Reactor | |
Capacitive pin 400kV | |
GDTF-520/260 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-260 |
Agbara (kVA) | 520 |
Ohun elo dopin | 110KV Circuit fifọ ati ọkọ akero |
110kV GIS | |
110kV (300 mm²) okun 800m | |
35kv (300 mm²) okun 3km | |
10kV (300 mm²) okun 6km | |
110kv kikun idabobo Amunawa | |
Awọn atunto akọkọ | 25kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
25kVA Moriwu transformer 1 ṣeto | |
Riakito 65kV / 2A 4sets | |
Capacitive pin 300kV | |
GDTF-500/500 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-500 |
Agbara (kVA) | 500 |
Ohun elo dopin | 220kV tabi isalẹ CT/PT |
220kV tabi isalẹ bushing | |
220kV tabi isalẹ Insulators, disconnectors | |
220kV tabi isalẹ Circuit fifọ | |
220kV tabi isalẹ Insulation Instrument | |
Awọn atunto akọkọ | 20kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
20kVA Moriwu transformer 1 ṣeto | |
Riakito 125kV / 1A 4sets | |
Capacitive pin 500kV | |
GDTF-600/600 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-600 |
Agbara (kVA) | 600 |
Ohun elo dopin | 110kV (300 mm²) okun 800m |
35kv (300 mm²) okun 110m | |
35-220kV GIS, Ayirapada, insulators | |
Awọn atunto akọkọ | 30kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
30kVA Moriwu transformer 1 ṣeto | |
Riakito 120kV / 1A 5sets | |
Capacitive pin 600kV | |
GDTF-800/800 | |
Foliteji igbewọle (V) | 380 |
Foliteji ti njade (kV) | 0-800 |
Agbara (kVA) | 800 |
Ohun elo dopin | 110kV (300 mm²) okun 800m |
220kv (300 mm²) okun 500m | |
35-500kV GIS, Ayirapada, insulators | |
Awọn atunto akọkọ | 40kW Ayipada orisun igbohunsafẹfẹ 1 ṣeto |
40kVA Moriwu transformer 1 ṣeto | |
Riakito 200kV / 1A 4sets | |
Capacitive pin 800kV |