GDYM-1A Ọkanṣoṣo Electric Energy Mita Calibrator
GDYM-1A Ipele Kanṣoṣo Electric Energy Meter Calibrator jẹ ohun elo wiwọn ọpọ-paramita eyiti o jẹ oni-nọmba ni kikun, iṣẹ-pupọ ati konge giga.Kii ṣe agbara nikan lati ṣe iwọn aṣiṣe, ṣugbọn tun lati wiwọn foliteji, iye ti o munadoko lọwọlọwọ, agbara ti nṣiṣe lọwọ, agbara ifaseyin, agbara gbangba, igbohunsafẹfẹ agbara, ifosiwewe agbara, ibatan alakoso, bbl O dara julọ fun calibrating išedede wiwọn ti Mita agbara eletiriki-ọkan ni ẹyọ ipese agbara.
Išišẹ ti o rọrun ati iyara, gbogbo awọn ilana ṣiṣe ti han loju iboju.
●Lati ṣe iwọn mita agbara ina ti eto wiwọn ati wiwọn ipin foliteji kekere.
●Lilo titun 32 bit 150MHz DPS mojuto ọna ẹrọ, 16 bit ga konge oluyipada, awọn aṣiṣe jẹ diẹ idurosinsin ati awọn išedede jẹ ti o ga (eyi ni o ni agbara iyato pẹlu nikan-alakoso calibrator pẹlu nikan-mita ërún).
●Iboju LCD ti o ni awọ ti o tobi, ṣafihan awọn aye eto calibrating, ti irẹpọ, awọn aye itanna, aṣiṣe ati gbogbo data wiwọn ni agbara.
●Dimole lọwọlọwọ ni a lo lati ṣe adaṣe lọwọlọwọ ti ipilẹṣẹ nipasẹ fifuye, eyiti o jẹ irọrun aaye ti n ṣiṣẹ ati imudara iṣẹ ṣiṣe.Awọn lọwọlọwọ ti ebute ati dimole bi agbara wọn ati apao agbara yoo han ni akoko kanna.
●Lilo dimole 500A ati dimole lọwọlọwọ kekere lati wiwọn ipin ti foliteji kekere CT.
●Ṣe iwọn data irẹpọ lati awọn akoko 2-43, lọwọlọwọ ati foliteji yoo ṣafihan akoko gidi ni fọọmu igbi kọọkan, eyiti o ṣe iranlọwọ lati ṣe idajọ ipo ipo-ojula.
●Iṣiro ibakan ti mita agbara ni akoko iṣọn agbara itanna kan.
●Fi data pamọ fun awọn mita 1000.
●Sopọ pẹlu PC nipasẹ RS232 jara ibaraẹnisọrọ ni wiwo.
●Pẹlu iṣelọpọ pulse igbohunsafẹfẹ kekere, rọrun fun ṣiṣe ayẹwo ara ẹni ati ayewo.
●Calibrator yoo ṣe itaniji nipasẹ ohun ati ina nigbati o n pese 380V si laini idanwo foliteji.
●Nigbati laini fifuye lọwọlọwọ jẹ aṣiṣe ti a ti sopọ si laini didoju ti mita, aabo aifọwọyi akọkọ kii yoo jade lọwọlọwọ.Nigbati o ba tun ṣe asopọ ẹbi lẹẹkansi, fiusi aabo keji yoo jo, eyiti o kan aabo pipe.Awọn calibrator yoo bọsipọ lẹhin ti o rọpo fiusi.
●Awọn fiusi yoo wa ni iná jade nigbatilaini igbiyanju lu 220V, calibrator yoo gba pada lẹhin ti o rọpo fiusi naa.
| Iwọn Iwọn | Yiye | ||
| Foliteji | 10-300V | ± 0.1% | |
| Simulation Lọwọlọwọ | 5A | ± 20% | |
| Dimole lọwọlọwọ | 100A, 500A | ± 0.3%, ± 0.5% | |
| Ibudo lọwọlọwọ | 0.05-10 A | ± 0.1% | |
| Agbara | Dimole lọwọlọwọ | 100A, 500A | ± 0.3%, ± 0.5% |
| Ebute | 10A | ± 0.1% | |
| Igun ipele | -180--+180° | ±0.1° | |
| Igbohunsafẹfẹ | 45-55Hz | ± 0.01Hz | |
| Itanna Agbara | 100A Dimole (kekere) | 0.25A-110A | ± 0.3%, ± 0.5% |
| 500A Dimole | 25-1000A | ± 0.5% | |
| Ifihan Ibiti | 100A lọwọlọwọ Dimole: 0.01A-110A | ||
| Ibudo: 0.01A-10A | |||
| Electric Energy Polusi | FL = 1000 imp/kW.h | ||
| Ṣiṣẹ Foliteji | AC 100 - 300 V | ||
| Awọn iwọn otutu ṣiṣẹ | -25 ℃~45 ℃ | ||
| Ọriniinitutu ṣiṣẹ | <95% Ko si isunmi | ||
| Iwọn | <1kg | ||
| Iwọn didun | 215 * 105 * 70mm | ||
| GDYM-1A Calibrator | 1 ṣeto |
| 100A dimole mita | 1 ona |
| Software Isakoso (CD-ROM) | 1 nkan |
| Itanna mita polusi ila | 1 nkan |
| okun foliteji | 1 nkan |
| Okun agbara | 1 nkan |
| 232 ibaraẹnisọrọ ila | 1 nkan |
| Photoelectric ori | 1 nkan |
| 0.5A fiusi | 1 nkan |
| Ọran irinse | 1 nkan |
| Afowoyi | 1 ẹda |