GDPQ-5000 Agbara Didara Oluyanju
Oluyanju Didara Agbara GDPQ-5000 jẹ ohun elo idanwo okeerẹ ni pẹkipẹki nipasẹ ile-iṣẹ wa ati apẹrẹ pataki fun idanwo aaye ti awọn ipele mẹta, iṣẹ-ọpọlọpọ ati oye, iṣiṣẹ ẹrọ-ẹrọ ṣoki.O rọrun lati lo, ifihan iboju LCD nla, ipinnu giga, wiwo ni Ilu Kannada ati Gẹẹsi mejeeji, eto ikarahun-mọnamọna ati bẹbẹ lọ.Le nigbakanna 4-ikanni lọwọlọwọ (ABC mẹta alakoso ati didoju waya lọwọlọwọ), 4-ikanni foliteji (ABC mẹta-alakoso foliteji ati didoju ila foliteji si ilẹ), awọn tente oke iye ti isiyi foliteji, o pọju / kere iye lori akoko kan. , Aiṣedeede aiṣedeede mẹta-mẹta, flicker foliteji igba diẹ, ifosiwewe iyipada K, agbara ti nṣiṣe lọwọ, agbara ifaseyin, agbara ti o han gbangba, ifosiwewe agbara ati ifosiwewe agbara iṣipopada, agbara ti nṣiṣe lọwọ, agbara ifaseyin, agbara ti o han gbangba, iparun irẹpọ lapapọ ati ibaramu, ati bẹbẹ lọ;Ṣe afihan igbi akoko gidi, awọn shatti igi ipin ibaramu ti foliteji lọwọlọwọ;Yiyi mu iyipada lẹsẹkẹsẹ ti lọwọlọwọ foliteji, ibojuwo ibẹrẹ lọwọlọwọ, mimojuto awọn aye agbara ati ṣe agbekalẹ atokọ itaniji, ṣe agbekalẹ apẹrẹ aṣa fun data idanwo igbasilẹ igba pipẹ.
GDPQ-5000 Oluyanju didara agbara gba DSP + ARM ile-iṣẹ iṣelọpọ ilọpo meji, DSP jẹ lilo fun gbigba data ati sisẹ algorithm, ARM ti wa ni lilo fun ilana ibaraẹnisọrọ ati sisẹ wiwo ẹrọ-ẹrọ;Gbigba ifihan agbara Analog jẹ nipasẹ awọn ege 2 AD7655 ti ile-iṣẹ ADI.Ipinnu fun AD7655 jẹ 16 bit ati pe o jẹ iṣapẹẹrẹ amuṣiṣẹpọ ikanni 4.Oṣuwọn iṣapẹẹrẹ ti o ga julọ le de ọdọ 1 MSPS, lati rii daju pe deede ti ikanni naa ati iduroṣinṣin alaye, ati pe kii yoo padanu eyikeyi awọn ayipada igba diẹ ninu akoj, o le ṣe deede diẹ sii lati rii fọọmu igbi igba diẹ ti o dide ati sisọ silẹ ni iyara, ati gbigbi idalọwọduro lẹsẹkẹsẹ ;Igbohunsafẹfẹ iṣẹ DSP ti kọja 200 MHZ, lati ni anfani lati ibojuwo akoko ti akoj agbara ati ni agbara lati ṣatunṣe igbohunsafẹfẹ iṣapẹẹrẹ lati mọ mimuuṣiṣẹpọ ti igbohunsafẹfẹ agbara ati igbohunsafẹfẹ iṣapẹẹrẹ;Lilo ifihan iboju awọ LCD 5.6-inch kan, ipinnu ti awọn aami 640 x 480, pẹlu iyatọ awọ ifihan oriṣiriṣi laarin awọn aye ti alakoso, igbi, aworan atọka, ipin ibaramu, olumulo le jẹ daradara ati oye diẹ sii ni oye ipo naa. ti agbara akoj sile.Iranti filasi ti a ṣe sinu le fipamọ awọn ẹgbẹ 60 ti awọn sikirinisoti ni akoko kanna, awọn ẹgbẹ 150 ti imudani foliteji igba diẹ / eeya igbi lọwọlọwọ, ati awọn ẹgbẹ 12800 ti atokọ itaniji.Bibẹrẹ awoṣe wiwa lọwọlọwọ le mu nigbagbogbo mu fọọmu igbi lọwọlọwọ fun awọn iṣẹju 100.Kaadi iranti 2G ti a ṣe sinu lati ṣafipamọ igbasilẹ aṣa aṣa, gbigbasilẹ nigbakanna awọn aye 20 (le yan ni ibamu si iwulo) gba data fun ẹẹkan ni iṣẹju-aaya marun, awọn igbasilẹ ti aṣa le wa ni ipamọ fun awọn ọjọ 300.
O tun pe ni oye Oluyanju Didara Agbara Alakoso mẹta, Oluyanju Didara Didara Multifunctional, eyiti o jẹ nigbakanna pẹlu awọn iṣẹ ti oluyanju ti irẹpọ, mita volt-ampere alakoso,itanna paramita ndan.O kan si ile-iṣẹ ina, petrochemical, metallurgy, ọkọ oju-irin, awọn ile-iṣẹ iwakusa, ile-iṣẹ iwadii imọ-jinlẹ, ẹka metrological.Paapa dara fun itupalẹ okeerẹ ati iwadii aisan lori gbogbo foliteji, lọwọlọwọ, agbara, agbara, irẹpọ, awọn aye ina mọnamọna alakoso.
2.1.Iṣẹ wiwọn
●Waveform gidi-akoko àpapọ (4 awọn ikanni foliteji / 4 awọn ikanni lọwọlọwọ).
●Awọn iye RMS otitọ ti awọn foliteji ati awọn ṣiṣan.
●Awọn paati DC ti awọn foliteji.
●Peak lọwọlọwọ ati foliteji iye.
●O kere ju ati iwọn idaji RMS lọwọlọwọ ati awọn iye foliteji.
●Ifihan aworan atọka Phassor.
●Wiwọn ti irẹpọ kọọkan titi di aṣẹ 50.
●Awọn shatti igi ṣe afihan awọn ipin ibaramu ti lọwọlọwọ ati foliteji ti ipele kọọkan.
●Lapapọ ipalọlọ ti irẹpọ (THD).
●Nṣiṣẹ, ifaseyin, agbara han, nipasẹ alakoso ati akojo.
●Nṣiṣẹ, ifaseyin, agbara han, nipasẹ alakoso ati akojo.
●Amunawa K ifosiwewe.
●Awọn ifosiwewe agbara (PF) ati awọn ifosiwewe nipo (DPF tabi COSΦ).
●Fikika foliteji igba kukuru (PST).
●Aidogba alakoso mẹta (lọwọlọwọ ati foliteji).
2.2.tionkojalo Yaworan iṣẹ
Mimojuto iyipada lẹsẹkẹsẹ ti awọn aye foliteji lọwọlọwọ agbara, pẹlu awọn iyipada foliteji lọwọlọwọ, iwọn foliteji lọwọlọwọ, sag ati idalọwọduro ipese kukuru, apọju igba diẹ, lọwọlọwọ ikolu ati ipalọlọ lọwọlọwọ foliteji lọwọlọwọ.Awọn ohun elo le ṣafipamọ awọn eto 150 ti ọna igbi igba diẹ ni akoko kanna.
2.3.Bibẹrẹ ibojuwo lọwọlọwọ
Mimojuto lọwọlọwọ ṣiṣan laini ati lọwọlọwọ ibẹrẹ nigbati ohun elo itanna ba bẹrẹ, ṣe iranlọwọ lati ṣe apẹrẹ ni deede.Le ṣe afihan igbi ti RMS ti nyara / ja bo Ninu ilana ibẹrẹ, ohun ti tẹ apoowe ti lọwọlọwọ ibẹrẹ, igbi ti awọn ikanni 4 lọwọlọwọ ati foliteji awọn ikanni 4.Gbigbasilẹ nipa awọn 100s lẹhin ti o nfa, tọju lọwọlọwọ / foliteji instantaneous ati igbi fọọmu ti iyipo kọọkan ni awọn 100s.
2.4.Igbasilẹ chart ti aṣa ati iṣẹ titoju
Tọju gbogbo awọn aye idanwo ti awọn iṣẹ idanwo ipilẹ (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF, W, VAR, VA, PF, COSφ, TANφ), 50 foliteji harmonics, 50 lọwọlọwọ harmonics.Ki o si ṣẹda awọn aṣa ti tẹ.Ṣe igbasilẹ data fun igba pipẹ ni ibamu si iwulo (aṣayan nigbakanna awọn aye 20 lati ṣe igbasilẹ data fun ẹẹkan ni iṣẹju-aaya marun, o le ṣe igbasilẹ nipa awọn ọjọ 300).
2.5.Iṣẹ itaniji
Ṣeto awọn iye iye ni ibamu si iwulo, mimojuto awọn iye boya overshoot, ti o ba ti overshoot yoo ṣe ina akọọlẹ itaniji kan, gẹgẹbi: foliteji, lọwọlọwọ, aiṣedeede, ipin irẹpọ, igbohunsafẹfẹ, agbara lọwọ, ipalọlọ ibaramu lapapọ.O le tunto awọn itaniji oriṣiriṣi 40, ẹgbẹ kọọkan le ṣeto awọn aye ibojuwo oriṣiriṣi (pẹlu 50 harmonics, lapapọ ti awọn aye oriṣiriṣi 123) ati awọn iye idiwọn, tun le ṣeto akoko kukuru ti overshoot.Iwe akọọlẹ le ni awọn itaniji to 12,800 ninu.
2.6.Iṣẹ aworan
Iboju eyikeyi le wa ni fipamọ (aworan iboju), ni akoko kanna ṣe igbasilẹ akoko ati ipo idanwo laifọwọyi.Iru bii o le fipamọ foliteji ati fọọmu igbi lọwọlọwọ, apẹrẹ igi irẹpọ, aworan atọka phasorati be be lo O le fipamọ iwọn iboju ti o pọju 60.
2.7.Iṣẹ ibaraẹnisọrọ
Ibaraẹnisọrọ pẹlu kọnputa nipasẹ USB, sọfitiwia Abojuto le ṣe afihan fọọmu igbi ti itupalẹ didara agbara, kika ti ọna igbi igba diẹ, gbigbasilẹ aworan aṣa, akọọlẹ itaniji, awọn sikirinisoti, ati ifihan lori kọnputa naa.
2.8.Eto iṣẹ
Olumulo le ṣe atunto akoko ati ọjọ, iṣeto ni itansan iboju ati imọlẹ, asọye ti awọn awọ igbi ipele kọọkan.
Yiyan iru asopọ si nẹtiwọki.
Iṣeto ni iru awọn sensọ lọwọlọwọ ati awọn ipin foliteji.
2.9.Akojọ iranlọwọ
Gbogbo ipele ti isẹ le tẹ bọtini "iranlọwọ" lati gba alaye ti o yẹ.
3.1.Ipo ipilẹ ati ipo iṣẹ
cIpa ipa | Ohun elo idanwo | Ipilẹ ipo | Ipo iṣẹ |
Iwọn otutu ayika | Gbogbo paramita | (23±2)°C | -10°C ~ 40°C |
Ojulumo ọriniinitutu | Gbogbo paramita | 40% ~ 60% | <80% |
Ipele-to-didoju foliteji | Gbogbo paramita | (100± 1%)V | 1.0V ~ 1000V |
Ipele-si-alakoso foliteji | Otitọ RMS alakoso-si-alakoso foliteji | (200± 1%)V | 1.0V ~ 2000V |
Lọwọlọwọ | Otitọ RMS lọwọlọwọ | (5±1%)A | 10mA ~ 10A |
Igbohunsafẹfẹ nẹtiwọki | Gbogbo paramita | 50Hz± 0.1Hz | 40Hz ~ 70Hz |
Iyipada alakoso | Agbara ti nṣiṣe lọwọ ati agbara ti nṣiṣe lọwọ | Kósφ=1 | Kosφ: 0.2 ~ 1.0 |
Agbara ifaseyin ati ifaseyin agbara | Sinφ=1 | Sinφ: 0.2~ 1.0 | |
ti irẹpọ | Gbogbo paramita | <0.1% | 0.0% ~ 100% |
Aidogba foliteji | Gbogbo paramita | <10% | 0.0% ~ 100% |
Ṣiṣẹ foliteji ti ẹrọ | Gbogbo paramita | DC9.8V± 0.1V | DC9.5V ~ 10.5V |
Aaye itanna ita, oofa aaye | Gbogbo paramita | Yẹ ki o yago fun | |
Ipo idanwo | Idiwon ibatan paramita ti lọwọlọwọ | Idanwo waya ni aarin ti dimole. |
3.2.Gbogbogbo sipesifikesonu
Ibi ti ina elekitiriki ti nwa | Batiri litiumu-ion gbigba agbara 9.6V, ṣaja afẹyinti. |
Atọka batiri | Aami batiri fihan agbara idalẹnu.Nigbati foliteji ba lọ silẹ ju, tiipa laifọwọyi lẹhin iṣẹju 1. |
Ilo agbara | Lilo lọwọlọwọ ti idanwo deede 490 mA, ṣiṣe tẹsiwaju fun awọn wakati 8. |
Ipo ifihan | LCD awọ iboju, 640dots × 480dots, 5,6 inches, àpapọ domain: 116mm × 88mm. |
Iwọn ti dimole | 008B kekere didasilẹ lọwọlọwọ dimole: 7.5mm × 13mm; |
Awọn iwọn irinṣẹ | L×W×H: 240mm×170×68 mm. |
Nọmba ti awọn ikanni | 4U/4I. |
Ipele-si foliteji alakoso | 1.0V ~ 2000V. |
Ipele-to-didoju foliteji | 1.0V ~ 1000V. |
Lọwọlọwọ | 008B lọwọlọwọ dimole: 10mA ~ 10.0A; |
Igbohunsafẹfẹ | 40Hz ~ 70Hz. |
Awọn paramita ti itanna | W, VA, Var, PF, DPF, cosφ, tanφ. |
Awọn paramita agbara | Wh, Varh, Wah. |
ti irẹpọ | Paṣẹ 0 ~ 50. |
Lapapọ ti irẹpọ iparun | Bere fun 0 ~ 50, ipele kọọkan. |
Ipo amoye | Bẹẹni. |
Nọmba ti Transient igbasilẹ | 150 ṣeto. |
Foliteji flicker | Bẹẹni. |
Bibẹrẹ ipo lọwọlọwọ | Bẹẹni, 100 aaya. |
Awọn ipele 3 aiṣedeede | Bẹẹni. |
Gba silẹ | Awọn ọjọ 300 (igbasilẹ nigbakanna awọn aye 20, ṣe igbasilẹ aaye kan ni gbogbo iṣẹju-aaya 5). |
Min/Max iye gbasilẹ | Wiwọn ti o pọju ati awọn iye to kere ju lori akoko kan. |
Itaniji | Awọn oriṣi 40 ti awọn yiyan paramita, 12,800 ṣeto awọn akọọlẹ itaniji. |
Oke | Bẹẹni. |
Ifihan aworan atọka Phassor | Laifọwọyi. |
Agbara ti snapshots | 60. |
Ede akojọ aṣayan | English |
Ibaraẹnisọrọ | USB. |
Pa a aifọwọyi | Nigbati ipolongo itaniji ba bẹrẹ tabi wiwa fun awọn igba diẹ, imudani inrush lọwọlọwọ, tabi gbigbasilẹ aṣa ti wa ni isunmọ tabi ti nlọ lọwọ, ẹrọ naa kii ṣe pipaarẹ laifọwọyi. |
Ni ipo idanwo miiran, iṣẹju 15 laisi awọn bọtini bọtini, tiipa laifọwọyi lẹhin iṣẹju 1. | |
Backlight iṣẹ | Bẹẹni, o dara fun lilo ni alẹ ati aaye dudu. |
Iwọn | Alejo: 1.6kg (pẹlu batiri). |
008B kekere didasilẹ lọwọlọwọ dimole: 170g × 4; | |
Gigun ti foliteji igbeyewo waya | 3m. |
Gigun ti okun sensọ lọwọlọwọ | 2m. |
Iwọn otutu ṣiṣẹati ọriniinitutu | -10 °C ~ 40 ° C;labẹ 80% Rh. |
Ibi ipamọ otutu ati ọriniinitutu | -10 °C ~ 60 ° C;labẹ 70% Rh. |
Input impedance | Imudani igbewọle ti foliteji idanwo: 1MΩ. |
Koju foliteji | Duro 3700V/50Hz sinusoidal AC foliteji fun iṣẹju 1 laarin wiwi irinse ati ikarahun. |
Idabobo | Laarin wiwu irinse ati ikarahun ≥10MΩ. |
Ilana | Idabobo ilopo, pẹlu idabobo gbigbọn-ẹri apofẹlẹfẹlẹ. |
Awọn ofin ailewu | IEC 61010 1000V ologbo III / 600V CAT IV, IEC61010-031, IEC61326, Idoti ìyí: 2. |
3.3.Itọkasi ohun elo (laisi sensọ lọwọlọwọ)
Ni atele ṣafihan data atẹle (lori ipilẹ awọn ipo ipilẹ ati awọn sensosi lọwọlọwọ bojumu, laini pipe, ko si iyipada alakoso).
Wiwọn | Ibiti o | Ipinnu ifihan | Aṣiṣe ti o pọju ni ibiti o ti itọkasi |
Igbohunsafẹfẹ | 40Hz ~ 70Hz | 0.01Hz | ± (0.03) Hz |
Otitọ RMS alakoso-to-didoju foliteji | 1.0V ~ 1000V | Ipinnu min 0.1V | ± (0.5%+5dgt) |
Otitọ RMS alakoso-si foliteji alakoso | 1.0V ~ 2000V | Ipinnu min 0.1V | ± (0.5%+5dgt) |
DC foliteji | 1.0V ~ 1000V | Ipinnu min 0.1V | ± (1.0%+5dgt) |
Otitọ RMS lọwọlọwọ | 10mA ~ 10A | Ipinnu min 1mA | ± (0.5%+5dgt) |
Peak ti alakoso-to-didoju foliteji | 1.0V ~ 1414V | Ipinnu min 0.1V | ± (1.0%+5dgt) |
Oke ti foliteji-si-alakoso | 1.0V ~ 2828V | Ipinnu min 0.1V | ± (1.0%+5dgt) |
Oke lọwọlọwọ | 10mA ~ 10A | Ipinnu min 1mA | ± (1.0%+5dgt) |
Oke ifosiwewe | 1.00 ~ 3,99 | 0.01 | ±(1%+2dgt) |
4.00 ~ 9,99 | 0.01 | ±(5%+2dgt) | |
Agbara ti nṣiṣe lọwọ | 0.000W ~ 9.999kW | Ipinnu min 0.001W | ± (1%+3dgt) Cosφ≥0.8 |
± (1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Agbara ifaseyin, inductive tabi capacitive | 0.000VAR ~ 9.999kVAR | Min ipinnu 0.001VAR | ± (1%+3dgt) Sinφ≥0.5 |
± (1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Agbara ti o han gbangba | 0.000VA ~ 9.999kVA | Ipinnu min 0.001VA | ± (1%+3dgt) |
Agbara ifosiwewe | -1.000 ~ 1.000 | 0.001 | ± (1.5%+3dgt) Cosφ≥0.5 |
± (1.5%+10dgt) 0.2≤Cosφ<0.5 | |||
Agbara ti nṣiṣe lọwọ | 0.000Wh ~ 9999.9MWh | Ipinu min 0.001Wh | ± (1%+3dgt) Cosφ≥0.8 |
± (1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Agbara ifaseyin, inductive tabi capacitive | 0.000VARh ~ 9999.9MVARh | Ipinnu min 0.001VARh | ± (1%+3dgt) Sinφ≥0.5 |
± (1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Agbara agbara | 0.000VAh ~ 9999.9MVAh | Ipinnu min 0.001VAh | ± (1%+3dgt) |
Igun alakoso | -179° ~ 180° | 1° | ±(2°) |
Tanφ (VA≥50VA) | -32.76 ~ 32.76 | Ipinnu min 0.001 | φ:±(1°) |
Ipele naficula ti agbara ifosiwewe (DPF) | -1.000 ~ 1.000 | 0.001 | φ:±(1°) |
Ipin ipin (paṣẹ 1 si 50)(Vrms>50V) | 0.0% ~ 99.9% | 0.1% | ±(1%+5dgt) |
Igun ti irẹpọ (Vrms>50V) | -179° ~ 180° | 1° | ± (3°) harmonics ti aṣẹ 1 si 25 |
± (10°) harmonics ti aṣẹ 26 si 50 | |||
Lapapọ ti irẹpọ ipin (THD tabi THD-F)≤50 | 0.0% ~ 99.9% | 0.1% | ±(1%+5dgt) |
ifosiwewe iparun (DF tabi THD-R)≤50 | 0.0% ~ 99.9% | 0.1% | ±(1%+10dgt) |
Amunawa K ifosiwewe | 1.00 ~ 99.99 | 0.01 | ± (5%) |
Awọn ipele 3 aiṣedeede | 0.0% ~ 100% | 0.1% | ± (1%) |
3.4.Ohun kikọ sensọ lọwọlọwọ
Iru sensọ lọwọlọwọ | Otitọ RMS lọwọlọwọ | Aṣiṣe ti o pọju ti lọwọlọwọ RMS otitọ | Aṣiṣe ti o pọju ti igun alakoso φ |
008B lọwọlọwọ dimole | 10mA ~ 99mA | ± (1%+3dgt) | ± (1.5°),Apa≥20mA |
100mA ~ 10.0A | ± (1%+3dgt) | ±(1°) | |
040B lọwọlọwọ dimole | 0.10A ~ 0.99A | ± (1%+3dgt) | ± (1.5°) |
1.00A ~ 100A | ± (1%+3dgt) | ±(1°) | |
068B lọwọlọwọ dimole | 1.0A ~9.9A | ±(2%+3dgt) | ±(3°) |
10.0A ~ 1000A | ±(2%+3dgt) | ±(2°) | |
300Flọwọlọwọ dimole | 10A ~99A | ± (1%+3dgt) | ±(3°) |
100A ~ 3000A | ± (1%+3dgt) | ±(2°) |
Akiyesi: dimole lọwọlọwọ ati awọn ohun elo gbọdọ wa ni asopọ si ibaramu, ko le fi sii idakeji.
4.1.Standard iṣeto ni
Rara. | Orúkọ | Opoiye |
1 | Irinse ogun. | 1 |
2 | Apo irinse. | 1 |
3 | Awọn sensọ lọwọlọwọ. | 12 (awọn oriṣi mẹta) |
4 | Awọn okun idanwo. | 5 (ofeefee, alawọ ewe, pupa, bulu, dudu) |
5 | Awọn agekuru ooni. | 5 |
6 | Iwadii idanwo. | 5 |
7 | Ifiṣootọ agbara ohun ti nmu badọgba. | 1 |
8 | Okun ọjọ USB. | 1 |
9 | CD software. | 1 |
10 | Litiumu batiri akopọ. | 1 (Ti a ṣe sinu ohun elo) |
11 | 2GB iranti. | 1 (Fi ẹrọ sinu ẹrọ) |
12 | Afowoyi, kaadi atilẹyin ọja, iwe eri. | 1 |
4.2.Iwọn
Rara. | Orúkọ | Iwọn |
1 | Irinse ogun. | 1.6kg (pẹlu batiri). |
2 | 008B kekere didasilẹ lọwọlọwọ dimole. | 170g*4. |
3 | 040B yikalọwọlọwọ dimole. | 185g*4 |
4 | 068B yikalọwọlọwọ dimole. | 530g*4 |
5 | 300FRọ okun lọwọlọwọdimole(pẹlu Integrator). | 330g*4 |
6 | Idanwo onirin ati agbara badọgba. | 900g. |