GDPQ-300E Agbara Didara Oluyanju
Oluyanju Didara Agbara GDPQ-300E jẹ ẹrọ amudani ti idanwo ati itupalẹ didara iṣẹ ṣiṣe eto agbara.O ṣe abojuto ati gba data ni akoko ṣiṣe pipẹ, tun pese itupalẹ irẹpọ ati itupalẹ didara agbara.Nibayi, o ni ipese pẹlu sọfitiwia itupalẹ data, nipasẹ eyiti o le gbe data iwọn si PC.
●ARM ati DSP, 16M baiti iranti.
●Iboju ifọwọkan, rọrun diẹ sii ati irọrun.
●Wiwọn data ati fifipamọ, le ṣe gbejade si PC.
●Module be, reasonable oniru ati ki o gbẹkẹle isẹ.
●Igbegasoke sọfitiwia irọrun ati irọrun.
●Itupalẹ alaye ti data iwọn nipasẹ sọfitiwia itupalẹ data didara agbara ni PC.
Awọn iṣẹ wiwa mita
No | Awọn nkan | Apejuwe |
1 | Foliteji / Lọwọlọwọ / Igbohunsafẹfẹ | O le wọn mẹta-foliteji alakoso, odo ila foliteji, mẹta alakoso lọwọlọwọ, odo ila lọwọlọwọ, igbohunsafẹfẹ. Le ṣe afihan RMS, iye ti o ga julọ, ipin igbi / tente oke, fọọmu igbi, awọn shatti aṣa ati bẹbẹ lọ. |
2 | Hihamọra igbi armonicment | O le wọn ipilẹ igbi ti foliteji ati lọwọlọwọ ati2-50 igba harmonicsigbi.Awọn abajade wiwọn pẹlu ṣiṣe irẹpọ, akoonu irẹpọ, akoonu irẹpọ, ati ipalọpọ ibaramu lapapọ (THD).Histograms ati awọn aṣa awọn aworan atọka, ati be be lo. |
3 | Interharmonic wiwọn | O le ṣe iwọn 0.1 ~ 19.9 igba interharmonics ti foliteji ati lọwọlọwọ.Awọn abajade wiwọn pẹlu awọn paati interharmonic ati awọn iye to munadoko ti ipin, iwọn akoonu interharmonic ati be be lo. o le ṣe afihan awọn histogram, awọn shatti aṣa, ati bẹbẹ lọ. |
4 | Iwọn agbara | O le wọn mẹta-alakoso mẹrin-waya / mẹta-alakoso mẹta-waya agbara han (agbara ina), ti nṣiṣe lọwọ agbara (agbara ina), ifaseyin agbara (agbara ina), agbara ifosiwewe ati be be lo., o le ṣe afihanaṣa shatti; le wọn ibeere of 1, 5, 10, 15, 30 60 iṣẹju. |
5 | Meta ipele aidogba odiwon | O lewiwọn mẹta-alakoso mẹrin-waya / mẹta-alakoso mẹta-waya itanna eto foliteji ati lọwọlọwọ rere ọkọọkan paati, odi ọkọọkan paati, odo ọkọọkan paati, odi ọkọọkan aiṣedeede ìyí, odo lesese iwọn;igun alakoso ti foliteji alakoso mẹta ati lọwọlọwọ,vector, aṣa awọn aworan atọka. |
6 | Flicker | 1 iseju flicker, 10 iseju flicker kukuru, 2 wakati gun flicker wiwọn |
7 | Foliteji wiwu / fibọ / Idilọwọ | Ṣe awari atiawọn akọọlẹ foliteji swells, sags ati interruptions iṣẹlẹ. |
8 | Srọ lọwọlọwọ | Ṣe awari ati awọn akọọlẹ gbaradi lọwọlọwọ iṣẹlẹ |
9 | Harmonic agbara | O le rii 2 ~ 30 igba harmonic agbara, le han histogram, aṣaawọn aworan atọka, ati be be lo. |
10 | Igbi agbara | Cwiwọn iyipada iyara ti agbara (lọwọ, ifaseyin, agbara gbangba) ni ibamu si akoko ti a ṣeto (iṣẹju 1 ~ 5) |
11 | Awọn iyipada | Cohun iwari foliteji transients to gun ju 20 microseconds |
8 | Igbasilẹ ibojuwo | O le ṣe igbasilẹ awọn aye didara agbara iduroṣinṣin fun igba pipẹ, pẹlu foliteji / lọwọlọwọ / igbohunsafẹfẹ, awọn irẹpọ, agbara, aiṣedeede mẹta-mẹta, iyipada / flicker, ati aarin gbigbasilẹ le ṣe atunṣe lati iṣẹju-aaya 3 si awọn iṣẹju 30. |
9 | Digital oscilloscope | Wo foliteji / lọwọlọwọ ifihan agbara igbi fọọmu |
Atọka deede kọọkan fun awọn iṣẹ wiwa
Nkan | Iwọn iwọn | Ṣe iwọn deede | Akiyesi |
Voltage / lọwọlọwọ / loorekoore | Tfoliteji alakoso hree: 1000V (iye ti o munadoko) Zero ila foliteji: 70V (munadoko iye) Three lọwọlọwọ lọwọlọwọ: 6000A (iye ti o munadoko, sensọ lọwọlọwọ 1000A fun iyan) Zero laini lọwọlọwọ: 25A (iye to munadoko) Fibeere: 40-70Hz | Foliteji:0.1%rdg±0.05% fs Lọwọlọwọ: 0.2%rdg±0.05% fs Frequency: kika±0.01Hz | HEre, a lo igbohunsafẹfẹ foliteji alakoso bi iwọn igbohunsafẹfẹ |
Iwọn igbi ti irẹpọ | Voltage ti irẹpọ: THD+Igbi ipilẹ+ 2-50times ti irẹpọ igbi. Cirẹpọ lọwọlọwọ: THD+Igbi ipilẹ+ 2-50times ti irẹpọ igbi. | Foliteji ti irẹpọ igbi: Uh≥1% UN±5%Uh; Uh.1% UN±0.05% UN Igbi ti irẹpọ lọwọlọwọ: Ih≥3% IN±5%Ih; Ih.3% IN±0.15% IN | |
Inter ti irẹpọigbiodiwọn | Voltage ti irẹpọ: 0.1 ~ 19.9 igbaInter harmonicigbi . Current ti irẹpọ: 0.1 ~ 19.9 igbaInter harmonicigbi | FolitejiInter harmonicigbi: Uih≥1% UN,5% Uih; Uih.1% UN,0.05% UN; LọwọlọwọInter harmonicigbi: Ih≥3% IN,5%Ih; Ih.3% IN,0.15% IN | |
Powo / Agbara itanna | Aagbara ti nṣiṣe lọwọ: 700kVA Rti nṣiṣe lọwọ agbara: 700kVAR Agbara ifosiwewe: 0.00 ~ 1.00 Aagbara agbara: 10000kWh Aagbara agbara gbangba: 10000kVAh Ragbara agbara: 10000kVARh Aapapọ agbara ifosiwewe: 0.00-1.00 | Ati nṣiṣe lọwọ: kika±0.5% Agbangba: kika±0.5% Ifaseyin: kika±0.5% Power ifosiwewe: kika±0.005 | |
Three alakoso aipin | Ffoliteji ailabawọn: 1000V (iye ti o munadoko) Flọwọlọwọ alailagbara: 6000A(iye to munadoko) Faibojumu igbohunsafẹfẹ: 40-70Hz Psibẹsibẹ igun: 0-360degree Uiwọntunwọnsi: 0.0% -100% | Volteji: 0,1% rdg±0.05% fs Clọwọlọwọ: 0.2%rdg±0.05% fs Frequency: kika±0.01Hz Psibẹsibẹ igun: kika±0.3 iwọn Voltage aipin: kika±0.2% Caidogba urrent: kika±0.2% | Nibi, a lo igbohunsafẹfẹ foliteji alakoso bi igbohunsafẹfẹ wiwọn lapapọ |
Foliteji Flicker | 1 iṣẹju flicker, kukuru akoko flicker, gun akoko flicker | 1 iseju flicker:±5.5% 10 iṣẹju kukuru flicker:±5% 2 wakati gun akoko flicker:≤±5% | |
Foliteji wú, fibọ ati idalọwọduro | Bojuto ati ṣe igbasilẹ gbigbi ipele-ọkan/pupọ-pupọ foliteji, fibọ foliteji ati pipa agbara igba diẹ | RMS idaji-igbi, akoko ibẹrẹ, iye akoko, aṣiṣe akoko ipari ± 10ms | Titi di awọn igbasilẹ iṣẹlẹ 40 |
Igbaradi Lọwọlọwọ | Atẹle ati ṣe igbasilẹ awọn ṣiṣan ṣiṣan ipele-ọkan/pupọ | Iye rms idaji-igbi, akoko ibẹrẹ, iye akoko, aṣiṣe akoko ipari ± 10ms | Duro idiwon nigba yiya iṣẹlẹ kan |
Harmonic agbara igbi | Lapapọ awọn akoko agbara irẹpọ: 1 ~ 30th Ti irẹpọ lapapọ agbara lọwọ:∑P Ti irẹpọ lapapọ agbara ifaseyin:∑Q Apapọ ti irẹpọ agbara ti nṣiṣe lọwọ: +∑P Apapọ ti irẹpọ odi agbara lọwọ: -∑P Agbara ifaseyin lapapọ ti irẹpọ to dara: +∑Q Lapapọ agbara ifaseyin ti irẹpọ odi: -∑Q | Ti irẹpọ agbara kika: ± 0.5% | |
Igbi agbara | O le ṣe awari gigun iṣẹju 1, 3, iṣẹju 5 ti nṣiṣe lọwọ, ifaseyin, iye agbara idaji-igbi ti o han gbangba, aṣa iyipada agbara gbigbasilẹ | Kika agbara idaji-igbi: ± 0.5% | |
Irekọja | Awọn iyipada foliteji ti o da lori iye ipin ti o ju 120% lọ | 1.to kere akoko ti awọn iṣẹlẹ asewon jẹ diẹ sii ju 20 microseconds 2.iṣeeṣe ti iṣẹlẹ iṣẹlẹ 98.7% | Awọn iṣẹlẹ 20 le wa ni ipamọ ni wiwọn kan |
Monitoring igbasilẹ | REcord paramita pẹlu foliteji, lọwọlọwọ, igbohunsafẹfẹ, foliteji/lọwọlọwọ ti irẹpọ igbi(lapapọ ti irẹpọ+1-25 igba harmonic), taiṣedeede ipele-hree;ti nṣiṣe lọwọ / ifaseyin / han agbara, agbara ifosiwewe;iyipada / flicker | Aarin ipamọ data: 3s ~ 30min Aarin naa jẹ 3s, ati akoko ibojuwo lapapọ jẹ 16h; Aarin jẹ iṣẹju 30, ati pe akoko ibojuwo lapapọ jẹ 960h. | |
Digital oscilloscope | Three alakoso foliteji, mẹta alakoso lọwọlọwọ, odo ila foliteji ati odo ila lọwọlọwọ igbi fọọmu | O pọju.igbohunsafẹfẹ iṣapẹẹrẹ: 200kHz Min.igbohunsafẹfẹ iṣapẹẹrẹ: 100Hz |
●Lupu ti nwọle ifihan agbara foliteji:
Wiwọle taara, ikọsẹ titẹ sii: 1MΩ, 20pF
Iwọn iwọn: foliteji iye to munadoko 1000V
Lilo agbara: kere ju 0.5VA/alakoso
●Loop igbewọle lọwọlọwọ:
Wiwọle aiṣe-taara
Iwọn wiwọn: Iwọn imunadoko lọwọlọwọ 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (yan sensọ lọwọlọwọ ti o baamu)
Lilo agbara: Kere ju 0.5VA/fase
●Iwọn ipo igbohunsafẹfẹ ifihan agbara: 40Hz-70Hz
●Iboju ifihan: 5.7 inch 640 * 480 LCD awọ pẹlu iboju ifọwọkan
●Ibi ipamọ iranti: 128M baiti FLASH
●Ibudo ipamọ ita: USB (pulọọgi sinu disk USB)
●Ipese agbara ṣiṣẹ: Li-batiri gbigba agbara, 5-6wakati ṣiṣẹ akoko fun idiyele ni kikun
●Ipese agbara: AC100-240V/DC 16.8V-1A ohun ti nmu badọgba agbara/ṣaja
Oludanwo | 1 ṣeto |
5A lọwọlọwọ dimole | 3 ona |
Foliteji igbeyewo waya | 1 nkan |
Adaparọ agbara | 1 nkan |
Iyipada waya | 1 nkan |
QC kọja | 1 ẹda |
Itọsọna olumulo | 1 ẹda |
Factory igbeyewo Iroyin | 1 ẹda |
Atokọ ikojọpọ | 1 ẹda |