GDYB-S3 Eto Igbeyewo Mita Agbara Ipele mẹta (awọn ipo 3)
Eto eto: 0.1%;
Paramita orisun ipele mẹta:
a.Foliteji ti njade:
3*57.7VY 3*100V ∆ ;
3*220V Y 3*380V ∆;
Iwọn adijositabulu 0 ~ 120% adijositabulu nigbagbogbo
Fifẹ atunṣe: dara ju 0.01%
b.Iwajade lọwọlọwọ: 25mA, 0.1A, 1A, 5A, 25A,100A;
Iwọn adijositabulu 0 ~ 120% adijositabulu nigbagbogbo
Fifẹ atunṣe: dara ju 0.01%
Iwajade kekere lọwọlọwọ: 1mA (ipeye: <5%)
c.O wu agbara: (foliteji Circuit) 3 * 50VA
(lọwọlọwọ Circuit) 3 * 150VA
d.Foliteji ti njade, lọwọlọwọ, iduroṣinṣin agbara: ≤0.02%/120S
e.Iwọn ipalọlọ ti foliteji iṣelọpọ ati ọna igbi lọwọlọwọ: ≤0.5%
f.Symmetry ti awọn igun alakoso mẹta: laarin 120°±0.3°
g.Iwọn igbohunsafẹfẹ: 45Hz~ 65Hz, igbesẹ: 0.01Hz
h.Iwọn igun ipele: -180°~ 180°, igbesẹ: 0.01°
i.Ntọkasi deedee mita: Voltmeter, ammeter: ± 0.01%
Mita ipele: ± 0.01°
Mita igbohunsafẹfẹ: ± 0.01Hz
Ilọjade ti o kere julọ: 1mA;deede: ≤5%;
Agbara fifuye (mita 20)
Iwọn foliteji: 800VA;
Ijade lọwọlọwọ: 2500VA;
Foliteji & atunṣe lọwọlọwọ
Ibiti a le ṣatunṣe: (0% ~ 120%) x iwọn iwọn;
Itanran ti o le ṣatunṣe: 10%, 1%, 0.1%, 0.01%;
Atunse ipele:
Iwọn to ṣatunṣe: 0 ° ~ 360 °;
Fifẹ adijositabulu: 10°, 1°, 0.1°, 0.01°;
Atunse loorekoore:
Ibiti a le ṣatunṣe: 45Hz ~ 65Hz;
Fifẹ ti o le ṣatunṣe: 1Hz, 0.1Hz, 0.01Hz;
Iduroṣinṣin agbara ti njade: ≤0.05% / 120S;
Foliteji igbejade & ipalọlọ lọwọlọwọ:
Foliteji: ≤0.5%;
Lọwọlọwọ: ≤0.5%;
Awọn eto ibaramu:
Nọmba ti irẹpọ: 2 ~ 21 igba;
Akoonu ti irẹpọ: lọwọlọwọ 2 ~ 21 igba ≤40% (i ibatan si igbi ipilẹ);
foliteji 2 ~ 21 igba ≤40% (ti o ni ibatan si igbi ipilẹ);
Ipele ti irẹpọ: 0 ° ~ 359.99 °;
Irinse ibojuwo:
Standard mita àpapọ išedede: Foliteji: 0,01%;
Lọwọlọwọ: 0.01%;
Agbara: 0.01%;
Ipele: 0.01;
Igbohunsafẹfẹ: 0.01;
Ya sọtọ 1:1 paramita transformer lọwọlọwọ:
Yiye: 0.01%;
Agbara ti njade: 60VA;
Iwọn wiwọn lọwọlọwọ: 1mA ~ 120A (1: 1);
Atọka iṣẹ ṣiṣe akọkọ
a) Yiye: 0.01% (COS∮=0.5C…1…0.5L);
b) Iwọn igbohunsafẹfẹ: 50Hz/60Hz± 5%;
c) Ibẹrẹ akọkọ: 3× 0.001-120A;
d) Atẹle lọwọlọwọ: 3× 0.001-120A;
e) Ẹru igbejade (apakan kọọkan):
0.5W (ibiti o wu jade: 0.001-1A);
0.7V pin nipasẹ iye lọwọlọwọ (ibiti o wu jade: 1-120A);
f) O wu fifuye foliteji: Max.0.5V (ijade lọwọlọwọ Max. 120A);
Iwọn iyipada lọwọlọwọ: 265 x 200 x 240 mm (L x W x H);
iwuwo: 12kg;
Iwọn:
Orisun Iṣakoso: 610 x 800 x 1920mm (L x W x H);
Mita agbeko: 2350 x 750 x 1850mm (L x W x H);