GD3127 Series High Foliteji idabobo Resistance igbeyewo
GD3127 Series Insulation Resistance Tester ti wa ni lilo pupọ ni itọju ohun elo itanna ni ile-iṣẹ iyipada, ọgbin agbara, bbl O dara fun gbigbe wiwọn ti idabobo idabobo (IR), atọka polarization (PI), ipin gbigba (DAR), rampu ( RAMP), àlẹmọ (FR, 10s, 20s, 30s, 40s 4 choices), foliteji (V), lọwọlọwọ (nA) ti gbogbo iru ohun elo foliteji giga, pẹlu switchgear, transformers, reactors, capacitors, Motors, Generators and kebulu, ati be be lo.
GD3127 Series jẹ ohun elo idanwo pipe fun idanimọ ni kutukutu ati iṣawari ti idena tabi awọn ero itọju asọtẹlẹ fun awọn ikuna ohun elo ti o pọju.O jẹ pataki nla lati rii daju didara ọja ati aabo ti eniyan ati ohun elo ni iṣẹ.Iṣẹ idabobo ti awọn ọja itanna jẹ ọkan ninu awọn ami pataki lati ṣe iṣiro didara idabobo, eyiti o ṣe afihan nipasẹ idanwo idabobo idabobo.
●O pọju.kukuru lọwọlọwọ> 5mA.
●Idaabobo idabobo (IR), itọka polarization (PI), ipin gbigba (DAR).
●Ramp (RAMP), àlẹmọ (FR), foliteji (V).
●Ṣe abojuto foliteji ifiwe laaye ti ohun elo ti o ni adaṣe, ati ṣe idiwọ idanwo naa laifọwọyi ti foliteji ba kọja 36V, eyiti o ṣe aabo ohun elo ati oniṣẹ ni imunadoko.
●Iṣẹ akoko, ṣe igbasilẹ akoko idanwo laifọwọyi.
●Fi foliteji giga silẹ laifọwọyi lẹhin wiwọn ti pari, akoko idasilẹ ko ju awọn aaya 30 lọ.
●Iṣẹ pipa agbara aifọwọyi.
●Ifihan matrix aami iboju iboju LCD nla pẹlu iṣẹ iduroṣinṣin.
●Eto ikarahun-Layer meji, to lagbara ati ti o tọ, ipele aabo IP65.
●Ididi batiri litiumu gbigba agbara nla.
●Iṣẹ ipamọ, le tọju awọn eto 1000 ti data idanwo akoko gidi pẹlu ọjọ idanwo ati akoko ati akoko idanwo.
●Iṣẹ ikojọpọ, ni ipese pẹlu wiwo USB, data igbasilẹ le ṣe gbejade si kọnputa fun itupalẹ iṣiro ti data.
| Išẹ | Idaabobo idabobo (IR), atọka polarization (PI), ipin gbigba (DAR), rampu (RAMP), àlẹmọ (FR, 10s, 20s, 30s, awọn yiyan 40s 4), foliteji (V), lọwọlọwọ (nA) |
| Ibi ti ina elekitiriki ti nwa | Gbigba agbarabatiri litiumu5.2 ah |
| Foliteji won won | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
| Foliteji o wu adeede | (5%-10%)±10V |
| Iwọn wiwọn resistance idabobo | GD3127:0.50MΩ~2.00TΩ GD3127B: 0.50MΩ~5.00TΩ |
| Kukuru Circuit lọwọlọwọ | > 5mA |
| Atọka isodipupo(PI) | Bẹẹni |
| Ipin gbigba (DAR) | Bẹẹni |
| Ipo idanwo Ramp (RAMP). | Idanwo ni awọn igbesẹ ti 10% ti foliteji tito tẹlẹ titi foliteji tito tẹlẹ |
| Àlẹmọ mode igbeyewo | Awọn yiyan mẹrin ti 10S, 20S, 30S, 40S |
| Igbeyewo foliteji | Ibiti o: AC/DC 0V-1000V, išedede:±5%rdg±3V |
| Idanwo lọwọlọwọ | Iwọn: 0.01nA-7mA, deede:±5%rdg±0.5nA |
| Atẹle foliteji | Ṣe abojuto foliteji ti nkan ti o ni idanwo, ṣe atẹle ipo idasilẹ lẹhin idanwo naa, ki o ṣe idiwọ idanwo naa nigbati foliteji ba tobi ju 36V, daabobo ohun elo ati oniṣẹ ẹrọ |
| Aago idanwo | Ṣe igbasilẹ akoko idanwo ni adaṣe, iwọn akoko: 0s~9999 ọdun |
| Ibi ipamọ | Ibi ipamọ aifọwọyi ti data idanwo pẹlu ọjọ ati akoko, apapọ awọn ẹgbẹ 1000 |
| Ibaraẹnisọrọ | Ṣe igbasilẹ data idanwo ti o fipamọ sori kọnputa nipasẹ laini ibaraẹnisọrọ USB. |
| Batiri | Ifihan ipele batiri wa, nrannileti lati gba agbara ni akoko nigbati foliteji batiri ba lọ silẹ |
| Aifọwọyi agbara pipa iṣẹ | Pa a laifọwọyi lẹhin iṣẹju 15 |
| Idaabobo kilasi | IP65/IP40 |
| Idaabobo idabobo | 50MΩ(1000V) (laarin iyika idanwo ati ikarahun) |
| Koju foliteji | AC 3kV 50Hz 1 iṣẹju (laarin iyika idanwo ati ikarahun) |
| Awọn ajohunše | IEC61010-1, IEC61326-1 |
| Ṣiṣẹ otutu ati ọriniinitutu | - 20℃ ~ +50℃ <80%RH |
| Ibi ipamọ otutu ati ọriniinitutu | -25℃ ~ +65℃80% RH |
| Ibi ti ina elekitiriki ti nwa | 220V AC 50Hz |
| Iwọn (mm) | 280(L)*260(W)*160 (H) |
| Iwọn | 4400g (batiri pẹlu) |
| Idanwo resistance idabobo | 1 ṣeto |
| Ga foliteji igbeyewo waya (pupa) | 1 nkan |
| Idanwo waya(Alawọ ewe) | 1 nkan |
| Idanwowaya(dudu) | 1 nkan |
| Adaparọ agbara | 1 piece |
| olumulo's itọsọna | 1 ẹda |
| Idanworgbejade | 1 ẹda |