VLF AC Hipot Igbeyewo Ṣeto 80kV
Idanwo foliteji duro jẹ idanwo idena pataki fun ohun elo itanna.O ti pin si meji awọn ẹya: AC ati DC withstand foliteji igbeyewo.Idanwo AC le pin siwaju si igbohunsafẹfẹ agbara, igbohunsafẹfẹ oniyipada ati 0.1Hz idanwo igbohunsafẹfẹ kekere pupọ, laarin eyiti eyiti o kẹhin jẹ iṣeduro gaan nipasẹ IEC, nitori awọn anfani iyalẹnu rẹ.
Atẹle jẹ lafiwe fun DC, Igbohunsafẹfẹ Agbara, Igbohunsafẹfẹ Ayipada, ati idanwo 0.1Hz.
Awọn ẹya | DC | Agbara Igbohunsafẹfẹ | Ayipada Igbohunsafẹfẹ | 0.1Hz |
Idogba | talaka | dara | dara | dara |
Ibajẹ idabobo | lagbara | diẹ | diẹ | diẹ |
Aabo isẹ | jo kekere | jo kekere | jo kekere | ga |
Iṣoro onirin | idiju | idiju | julọ idiju | rọrun |
Iwọn didun | kere julọ | tobi julo | nla | kekere |
Ni otitọ idanwo VLF jẹ aropo fun idanwo igbohunsafẹfẹ agbara.O dara fun idanwo ohun elo itanna pẹlu agbara nla (bii okun agbara, kapasito agbara, mọto, ati monomono).
Iran tuntun ti VLF jara 0.1Hz VLF AC Hipot Test Set ni idagbasoke nipasẹ HV Hipot gba eto idanwo agbara oye “Smart Quick” (Nọmba 1010215, nọmba iforukọsilẹ aami-iṣowo 14684781), ile-iṣẹ HV HIPOT ṣafihan awọn paati itanna agbara kariaye tuntun ati imọ-ẹrọ microcontroller tuntun ARM7, siwaju idinku iwọn ati iwuwo ti ẹrọ naa.Išišẹ naa rọrun, ati pe iṣẹ naa jẹ iduroṣinṣin diẹ sii.
●Imọ-ẹrọ to ti ni ilọsiwaju gba imọ-ẹrọ iyipada igbohunsafẹfẹ oni-nọmba, iṣakoso microcomputer ni kikun laifọwọyi, igbelaruge foliteji, igbesẹ-isalẹ, wiwọn, aabo, ati bẹbẹ lọ.
●Apakan iṣakoso ati apakan giga-giga gba apẹrẹ eto imudarapọ, ati pe okun waya foliteji giga nikan ati okun waya ilẹ ni a nilo lati sopọ si ọja idanwo laisi okun waya asopọ agbedemeji.
●Apẹrẹ ara Trolley jẹ irọrun fun gbigbe ni ọpọlọpọ awọn agbegbe iṣẹ, ati iwọn kekere ati iwuwo ina jẹ itara pupọ si awọn iṣẹ ita (80kV).
●Idaabobo lori-foliteji ati aabo lọwọlọwọ.Akoko igbese ko ju 10ms lọ.
●Ẹka iṣakoso ati igbelaruge ti sopọ ni foliteji kekere, pẹlu iṣakoso ipinya fọtoelectric, ailewu ati igbẹkẹle lati lo.
●Circuit esi odi ti o tii-pipade ti gba.Ko si agbara ti o ga soke lakoko iṣelọpọ.
●Iboju ifọwọkan Capacitive, ifihan ayaworan LCD, ibi ipamọ aifọwọyi, ati titẹ sita.
●0.1Hz, 0.05Hz ati 0.02Hz ni a le yan, eyiti o ṣe idaniloju iwọn idanwo jakejado.
●Foliteji ti o pọju: 80kV
●Igbohunsafẹfẹ: 0.1Hz, 0.05Hz ati 0.02 Hz (yiyan)
● Maximum load capacity: 1.1μF@0.1Hz / 2.2μF@0.05Hz / 5.5μF@0.02Hz
●Iwọn wiwọn: 3%.
●Aṣiṣe iye iwọn foliteji: ≤3%.
●Iyipada fọọmu foliteji: ≤5%.
●Ayika iṣẹ: inu tabi ita gbangba;-10℃-+40℃;85% RH
●Fiusi: 20A
●Ipese agbara: 220V ± 10%, 50Hz ± 5% (Ti o ba nlo monomono to ṣee gbe, rii daju pe foliteji iṣelọpọ ati igbohunsafẹfẹ jẹ iduroṣinṣin. Agbara> 3kW, igbohunsafẹfẹ 50Hz, foliteji 220V± 5%).
●Agbara ohun elo ti o ni idanwo ko gbọdọ kọja iwọn.won won capacitance ti awọn irinse.