Amunawa Epo Gas Chromatography Online Monitoring System
GDDJ-DGA Transformer Oil Gas Analyzer jẹ ẹrọ ibojuwo ori ayelujara fun gaasi tituka ninu epo iyipada ti o da lori imọ-ẹrọ kiromatogirafi gaasi.Aṣiṣe ti o pọju ti pinnu, gbigbọn itusilẹ gẹgẹbi iye tito tẹlẹ nipasẹ eto ayẹwo iwé.
Ẹrọ naa gba imọ-ẹrọ iṣapẹẹrẹ iṣakoso pinpin pinpin ati pe o ni idanimọ ara ẹni ati awọn iṣẹ imularada ara ẹni.Module iṣẹ kọọkan jẹ isọpọ alailagbara, ominira iṣẹ, gbigbe igbekalẹ agbeko, rọrun fun itọju imọ-ẹrọ.
●Ọfẹ itọju, ko si iwulo lati rọpo silinda gaasi.
●Wiwa lori laini ifọkansi ati oṣuwọn idagbasoke ti H2, CO, CO2, CH4, C2H4, C2H2, C2H6.
●Apẹrẹ apọjuwọn ati ilana iwapọ, rọrun fun itọju, pẹlu ilọpo giga, le ni irọrun ṣepọ si ohun elo ibojuwo miiran.
●Ipo iṣapẹẹrẹ ọmọ mimọ pipo, lati ṣe afihan ipo gaasi tituka ninu epo iyipada.
●Pumpless igbale degassing ọna ẹrọ, ko si nilo igbale fifa ati ki o mu dede ati iduroṣinṣin ti eto.
●Ọwọn chromatographic eka pataki, lati mu ilọsiwaju ipinya ti akopọ gaasi.
●Oluwari laini pataki, data ibojuwo jẹ gidi ati igbẹkẹle, awọn abajade idanwo wa nitosi data yàrá.
●Apakan ominira laarin chassis lati ṣakoso iwọn otutu ati ọriniinitutu, lati yọkuro ipa agbegbe ati akoko.
●Pẹlu ga data akomora konge, o adopts △-ε 24-nọmba ADC ati oni-nọmba àlẹmọ.O nlo isọdiwọn adaṣe lati gba spectrogram.
●Pẹlu ọpọlọpọ ifihan data ati awọn ipo ibeere, ijabọ ati aworan aṣa.Awọn data itan le wa ni fipamọ to ọdun 10.
●Iyipada ayika ti o lagbara, ohun elo aṣeyọri ni otutu, iwọn otutu giga, ọriniinitutu giga, agbegbe giga giga.
●Agbara kikọlu ti o lagbara, ibaramu itanna le ni itẹlọrun boṣewa ti o yẹ.
●Pẹlu awọn ipele meji ti iṣẹ itaniji, ifihan agbara itaniji le tan kaakiri.
●Yiyara onínọmbà ọmọ, kere monitoring ọmọ ni 40 iṣẹju, le ti wa ni ṣeto nipasẹ awọn olumulo.
●Imọ-ẹrọ ipadabọ epo pipe, lakoko ilana idọti, apẹẹrẹ epo ko kan si gaasi ti ngbe chromatogram, lilo awọn ọna oriṣiriṣi ti iṣakoso, lati rii daju pe ara iyipada pada ti apẹẹrẹ epo ni kikun pade awọn ibeere.
●Eto ayẹwo eto ti o lagbara, awọn abajade ni a fun nipasẹ ọna iwọn mẹta ti ilọsiwaju, ọna onigun mẹta David ati ọna aworan atọka cube.
●Pẹlu orisirisi awọn ọna ibaraẹnisọrọ lati gbe data, RS485, IEC61850, GPRS alailowaya gbigbe ati kukuru ifiranṣẹ ti wa ni loo lati gbe data.
●Ṣe atilẹyin asopọ Ethernet / opiti, gbigbe data, iṣakoso ẹrọ ati eto paramita pẹlu oni-nọmba ni kikun ati iṣakoso latọna jijin.
●Isọdi adaṣe epo / gaasi ati awọn iṣẹ mimọ adaṣe wa.
Iwọn otutu ayika | -40℃~+ 70 ℃ | ||
Ọriniinitutu ayika | Ọriniinitutu ibatan 5-95% (ko si isunmi) | ||
Afẹfẹ Ipa | 80kPa-110kPa | ||
Ibi ti ina elekitiriki ti nwa | AC 220V± 10%, 50Hz | ||
Abojuto irinše | H2, CO, CO2, CH4, C2H4, C2H2, C2H6, H2O, oṣuwọn idagbasoke ati ifọkansi | ||
Onínọmbà ati iṣẹ ayẹwo | Ṣe itupalẹ ati ṣe iwadii data ibojuwo nipasẹ ọna ipin mẹta, ọna onigun mẹta David ati ọna aworan atọka cube.Atilẹba spectrogram le wa ni ipese. | ||
Min.Ayika wiwa | 40-60mins, asọye olumulo, aiyipada ni igba mẹrin ni ọjọ kan. | ||
Ipo iṣapẹẹrẹ | Ayẹwo gigun kẹkẹ, lati ṣe afihan ipo gidi-akoko ti gaasi inu. | ||
Iyapa mode ti epo ati gaasi | Igbale degassing mode, degassing fun igba mẹta continuously. | ||
Igbesi aye ipamọ data | ≥ 10 ọdun | ||
Ti ngbe gaasi opoiye | Gaasi ti ngbe ti ara ẹni, ko ni idilọwọ ni gbogbo ọdun yika.Ko si ye lati ropo gaasi silinda. | ||
gaasi ibojuwo | Iwọn iwọn | Min.wiwa | Asise |
H2 | 2-2000 ppm | 1ppm | ± 10% |
CO | 5-20000 ppm | 5ppm | ± 10% |
CH4 | 0.2-2000 ppm | 0,2ppm | ± 10% |
C2H4 | 0.2-2000 ppm | 0,2ppm | ± 10% |
C2H6 | 0.2-2000 ppm | 0,2ppm | ± 10% |
C2H2 | 0.2-2000 ppm | 0,2ppm | ± 10% |
CO2 | 25-20000 ppm | 25 ppm | ± 10% |
H2O | 1-800 ppm | ||
Epo otutu | -40℃ ~ 200℃ | ||
Lapapọ opoiye afẹfẹ | 0.2-15% | ||
Apapọ hydrocarbon | 1-8000 ppm | ||
Iduroṣinṣin (aṣiṣe wiwọn) | Ni ipo idanwo kanna, aṣiṣe ko ju 10% fun apẹẹrẹ epo kanna.(ifojusi alabọde) | ||
IP kilasi | IP66 |
Giga | ≤3000m |
Ibaramu otutu | -10℃~+45℃(ninu ile);-40℃~+70℃(ita ita) |
O pọju.ojoojumọ otutu iyato | 25 ℃ |
O pọju.ojulumo ọriniinitutu | 95% (apapọ ojoojumọ);90% (apapọ oṣooṣu) |
Afẹfẹ titẹ | 86kPa ~ 106kPa |
Anti-mọnamọna agbara | Petele isare 0.30g;inaro isare 0,15g |
Ayika fifi sori | Fi sori ẹrọ inu ile.Yara naa gbọdọ wa ni ipese pẹlu ẹrọ amúlétutù, ko si idabobo, laisi awọn igbese anti-aimi. |
Ipese agbara ti o ni iwọn (AC) | 220V / 100V, aṣiṣe iyọọda ± 20% (harmonics), apapọ ipalọlọ foliteji oṣuwọn ≤8%. |
Ipese agbara ti o ni iwọn (DC) | 220V/110V, iyọọda iyatọ ibiti ± 20%. |
Ti won won AC foliteji | 57.7V/100V/220V, apọju agbara jẹ 1.2times ti won won foliteji, tente olùsọdipúpọ ≥2. |
Ti won won AC lọwọlọwọ | 1A/5A, agbara apọju jẹ awọn akoko 1.2 ti lọwọlọwọ ti wọn ṣe, n ṣiṣẹ nigbagbogbo, alasọdipúpọ ≥3. |
Iwọn igbohunsafẹfẹ | 50Hz, aṣiṣe iyọọda -5% ~+5%. |
Ibi ti ina elekitiriki ti nwa
Ipese agbara ti eto ibojuwo ipo substation yẹ ki o jẹ ailewu ati igbẹkẹle, ati ohun elo Layer iṣakoso ibudo yẹ ki o ni agbara nipasẹ 220VAC Ipese Agbara Ailopin (UPS).Ẹka ibojuwo kọọkan ninu ilana ilana ni agbara nipasẹ 220V AC eto.
Idaabobo monomono, grounding, egboogi-kikọlu
Eto ibojuwo ipo ile-iṣẹ yoo ni awọn igbese aabo lodi si iwọn-foliteji.
Ko si akoj grounding lọtọ fun eto ibojuwo ipo.Ni ibamu si awọn opo ti "ọkan-ojuami grounding", ilẹ waya ti wa ni ti sopọ si ọkan ojuami ti awọn ifilelẹ ti awọn grounding akoj ti awọn substation.
Ẹrọ aabo ti o ju-foliteji yoo wa ni fi sori ẹrọ lori ipese agbara 220V AC, laini ibaraẹnisọrọ ati opin opin ti nẹtiwọọki ilẹ, ati awọn aye ẹrọ aabo yoo ni ibamu si atọka iṣẹ idabobo ti ẹrọ naa.
Awọn ẹnjini, minisita ati okun shielding Layer ti awọn majemu monitoring eto yẹ ki o wa lori ilẹ ni igbẹkẹle.Isopọ laarin awọn ipele ilana ti eto ibojuwo ipo, asopọ laarin ilana ilana ati Layer iṣakoso ibudo, ati asopọ laarin awọn ebute oko ibaraẹnisọrọ ti ẹrọ naa gbọdọ ya sọtọ.
Awọn ẹrọ ti wa ni ti fi sori ẹrọ ni yara kan lai itanna shielding.Ẹrọ funrararẹ yẹ ki o pade awọn ibeere ti kikọlu aaye anti-itanna ati ipa elekitirosita.Ni ọran ti iwọn monomono, apọju iṣiṣẹ ati aṣiṣe kukuru kukuru ti ohun elo akọkọ, ohun elo naa ko ni ṣiṣẹ daradara, ati pe gbogbo ohun elo gbọdọ pade awọn ibeere ilodi si kikọlu atẹle wọnyi:
1) Fun itujade elekitirotiki, o ni ibamu si GB/T 17626-4-2 kilasi 4.
2) Fun aaye itanna itanna, o ni ibamu si GB/T 17626-4-3 kilasi 3.
3) Fun igba akoko iyara, o ni ibamu si GB/T 17626-4-4 kilasi 4.
4) Fun iṣẹ abẹ, o ni ibamu si GB/T 17626-4-5 kilasi 3.
5) Fun itọsi ifakalẹ itanna, o ni ibamu si GB/T 17626-4-6 kilasi 3.
6) Fun aaye itanna igbohunsafẹfẹ agbara, o ni ibamu si GB/T 17626-4-8 kilasi 4.
7) Fun aaye itanna eletiriki, o ni ibamu si GB/T 17626-4-9 kilasi 5.
8) Fun aaye oofa oscillating ọririn, o ni ibamu si GB/T 17626-4-10 kilasi 5.
9) Fun awọn igbi oscillating, o ni ibamu si GB/T 17626-4-12 kilasi 2 (ibudo ifihan agbara).
Rara. | Orukọ ohun elo | Awọn pato | Qty | Akiyesi |
1 | Amunawa Oil Gas Online monitoring eto | 535*600*1100 | 1 | |
2 | Flange | Da lori ibudo ti transformer | 2 | |
3 | Irin alagbara, irin tube | Φ6*30M | 1 | |
4 | Okun opitika | Multimode 4-mojuto, 200M | 1 | |
5 | Apoti ebute | 2 | ||
6 | Jumper | SC-SC | 2 | |
7 | Okun converter | multimode | 1 | |
8 | okun àjọlò | 0.5M | 2 | |
9 | Dabaru | M12*1.25M, Φ6 | 2 | |
10 | Imugboroosi dabaru | M10*100 | 4 | |
11 | Bọtini minisita | 2pcs | 1 | |
12 | Kaadi USB | 4pcs + ọpọlọpọ awọn asopọ okun ọra | 1 | |
13 | Irin alagbara, irin tube | Φ3*2M | 1 | |
14 | Pipe idabobo ati awọn miiran irinše | Pipe idabobo Φ6 * 2M 4pcs, Au teepu 50 * 25M 1roll, irin alagbara, irin hoop 8 * 32 2pcs | 1 |