GLF-314 SF6 Gas Infurarẹẹdi Aworan Leak Oluwari
● Ifihan ogbon inu ti ipo jijo gaasi ni akoko gidi.
● Ipo infurarẹẹdi ti o ni ilọsiwaju gaasi lati ṣawari awọn n jo gaasi kekere pupọ.
● Eto iṣẹ ti a fi sii, apẹrẹ UI ti o jọra si foonu alagbeka ati tabulẹti jẹ ki o rọrun fun awọn olumulo lati bẹrẹ.
● USB, WiFi, HDMI ọpọ awọn ọna gbigbe data.
● Ifihan LCD rotatable ti o ga.
● Wiwo ti o ga-giga pẹlu igun adijositabulu fun ina didan.
● Lightweight, logan oniru.
● Anti-rirẹ ergonomic oniru.
● Ogun alaworan agbalejo
● Adaparọ agbara
● Litiumu-Ion awọn batiri gbigba agbara ati ṣaja
● okun USB
● HDMI okun fidio
●32G TF kaadi iranti ati oluka kaadi
● Itọsọna olumulo
● Apoti iṣakojọpọ
N0. | Awọn nkan | Awọn pato | |
1 | Oluwari ati opitika paramita | Iru oluwari | Ti ko tutuinfurarẹdidelectors |
2 | Ipinnu infurarẹẹdi | 384×288 | |
3 | Piksẹli aaye | 25μm | |
4 | Àlẹmọ bandpass weful esi | 7μm-8.5μm,9.5μm -12μm | |
5 | Ifamọ igbona (NETD) | <0.1℃ @ 30℃ | |
6 | Gaasi ti a rii | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Infurarẹẹdi lẹnsi | Standard lẹnsi(21,7°±2°)× (16,4°±2°) | |
8 | Infurarẹẹdi idojukọ | Afowoyi & adaṣe | |
9 | Ifihan aworan | Sun-un oni nọmba | 1 to 10 igba lemọlemọfún oni sun-un |
10 | Iwọn fireemu aworan | 50Hz±1Hz | |
11 | Ipinnu ifihan | 1024×600 | |
12 | Iboju ifihan | 5-inch iboju ifọwọkan, ipinnu 1024×600 | |
13 | Oluwari | Ifihan OLED ti o ga, 1024 x 600 awọn piksẹli | |
14 | Ipo ifihan | Ipo infurarẹẹdi. Ipo igbelaruge gaasi. Ipo wiwọn otutu infurarẹẹdi. Ipo ina han. Aworan-ni-aworan mode. Ipo idapọ; | |
15 | Atunṣe aworan | Imọlẹ aifọwọyi ati afọwọṣe ati atunṣe itansan | |
16 | Paleti | 10 orisi + 1 olumulo-telẹ | |
17 | Kamẹra oni nọmba | Aaye wiwo jẹ ibamu pẹlu lẹnsi infurarẹẹdi | |
18 | Awọn imọlẹ LED | Bẹẹni | |
19 | Iwọn iwọn otutu ati itupalẹ | Iwọn wiwọn iwọn otutu | 1 ohun elo:-20 - 150 ° C 2 ohun elo:100 - 650 ° C |
20 | Yiye | ± 3 ℃or ± 3%(Mu iye ti o tobi julọ, iwọn otutu ibaramu jẹ 15 ° C si 35 ° C) | |
21 | Iwọn iwọn otutu aaye aarin | Bẹẹni | |
22 | Iwọn iwọn otutu aaye gbigbe | Ṣe atilẹyin awọn aaye 10 | |
23 | Iwọn iwọn otutu agbegbe gbigbe | Ṣe atilẹyin awọn iyika 10 ati awọn onigun mẹrin 10 | |
24 | Iwọn iwọn otutu laini gbigbe | Ṣe atilẹyin awọn ila 10 | |
25 | Ga ati kekere otutu ojuami aye | Ṣe atilẹyin iboju kikun giga ati ipo ipo iwọn otutu kekere ati ipo ipo iwọn otutu giga ati kekere ni agbegbe | |
26 | Tito wiwọn | Ko si wiwọn, aaye aarin, aaye iwọn otutu ti o pọju, aaye iwọn otutu ti o kere ju, iwọn otutu apapọ | |
27 | Itaniji iwọn otutu | Awọn itaniji awọ (awọn ila isothermal): loke/isalẹ awọn ipele iwọn otutu pato, laarin awọn ipele iwọn otutu pàtó. Awọn itaniji iṣẹ wiwọn: Awọn itaniji ti n gbọ (loke/isalẹ/laarin awọn ipele iwọn otutu ti a ti sọ tẹlẹ). | |
28 | Atunse iye iwọn | Emissivity (0.01 si 1.0 yiyan), iwọn otutu afihan, ọriniinitutu ibatan, iwọn otutu oju aye, ijinna ibi-afẹde, isanpada ir window ita | |
29 | Ibi ipamọ ọjọ | Alabọde ipamọ | Kaadi iranti TF yiyọ kuro |
30 | Ya awọn aworan nigbagbogbo | 3 iṣẹju-aaya si awọn wakati 24 | |
31 | Abinibi kikun radiometric image onínọmbà | Awọn aworan igbona radiometric ti o fipamọ le jẹ satunkọ ati itupalẹ lori kamẹra | |
32 | Aworan faili kika | Awọn aworan JPEG boṣewa, pẹlu awọn fọto oni-nọmba ati data radiometric ni kikun | |
33 | Igbasilẹ fidio infurarẹẹdi Radiometric | Gbigbasilẹ fidio itankalẹ gidi-akoko, * .aise faili ti wa ni ipamọ ni kaadi TF | |
34 | Igbasilẹ fidio infurarẹẹdi ti kii ṣe itanna | * .avi fidio faili, fi si TF kaadi | |
35 | Aworan alaye | Ohùn: 60 aaya, ti o fipamọ pẹlu aworan Ọrọ: Ṣafikun tabili, yan laarin awọn awoṣe asọye | |
36 | Wiwo ifihan latọna jijin | Wo awọn ṣiṣan fidio ni akoko gidi lori Wi-Fi kanasopọ. Sopọ si ifihan nipasẹ HDMI wiwo-giga ni wiwo; | |
37 | Latọna isẹ iṣakoso | Sopọ si iṣakoso sọfitiwia igbẹhin nipasẹ Wi-Fi; | |
38 | Ibaraẹnisọrọ ati awọn pẹẹpẹẹpẹ | ni wiwo | USB 2.0, Wi-Fi, HDMI |
39 | WIFI | Bẹẹni | |
40 | Ohun | Gbohungbohun ati agbọrọsọ fun asọye ohun aworan ati gbigbasilẹ fidio | |
41 | ijuboluwole lesa | Bẹẹni | |
42 | GPS | Ṣe atilẹyin ipo satẹlaiti, alaye ipo le wa ni fipamọ ni aworan naa | |
43 | Ibi ti ina elekitiriki ti nwa | Iru batiri | Batiri itanna litiumu gbigba agbara |
44 | Batiri foliteji | 7.4v | |
45 | Ilọsiwaju akoko iṣẹ | Ko kere ju wakati 4 ni iwọn otutu yara | |
46 | Ipese agbara ita | Ṣe atilẹyin ipese agbara dc12v ita | |
47 | Isakoso agbara | Tiipa aifọwọyi tabi pipa iboju aifọwọyi, akoko le yan lati rara, 5min, 10min, 30min | |
48 | Ayika aṣamubadọgba
| Awọn iwọn otutu ti nṣiṣẹ | -20-+ 50 ℃ |
49 | Iwọn otutu ipamọ | -40-+ 70 ℃ | |
55 | Awọn ohun-ini ti ara | Iwọn (laisi batiri) | ≤ 1.8 kg |
56 | Awọn iwọn (H*W*L) | ≤185 mm × 148 mm × 155 mm (pẹlu awọn lẹnsi boṣewa) | |
57 | Tripod òke mimọ | Iwọnwọn,1/4"-20 |
● Ifihan ogbon inu ti ipo jijo gaasi ni akoko gidi.
● Ipo infurarẹẹdi ti o ni ilọsiwaju gaasi lati ṣawari awọn n jo gaasi kekere pupọ.
● Eto iṣẹ ti a fi sii, apẹrẹ UI ti o jọra si foonu alagbeka ati tabulẹti jẹ ki o rọrun fun awọn olumulo lati bẹrẹ.
● USB, WiFi, HDMI ọpọ awọn ọna gbigbe data.
● Ifihan LCD rotatable ti o ga.
● Wiwo ti o ga-giga pẹlu igun adijositabulu fun ina didan.
● Lightweight, logan oniru.
● Anti-rirẹ ergonomic oniru.
●Olutọju alaworan ti o gbona
● Adaparọ agbara
● Litiumu-Ion awọn batiri gbigba agbara ati awọn ṣaja
● okun USB
● HDMI fidio USB
●32G TF kaadi iranti ati oluka kaadi
● Itọsọna olumulo
●Apoti iṣakojọpọ
N0. | Awọn nkan | Awọn pato | |
1 | Oluwari ati opitika paramita | Iru oluwari | Ti ko tutuinfurarẹdidelectors |
2 | Ipinnu infurarẹẹdi | 384×288 | |
3 | Piksẹli aaye | 25μm | |
4 | Àlẹmọ bandpass weful esi | 7μm-8.5μm,9.5μm -12μm | |
5 | Ifamọ igbona (NETD) | <0.1℃ @ 30℃ | |
6 | Gaasi ti a rii | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Infurarẹẹdi lẹnsi | Standard lẹnsi(21,7°±2°)× (16,4°±2°) | |
8 | Infurarẹẹdi idojukọ | Afowoyi & adaṣe | |
9 | Ifihan aworan | Sun-un oni nọmba | 1 to 10 igba lemọlemọfún oni sun-un |
10 | Iwọn fireemu aworan | 50Hz±1Hz | |
11 | Ipinnu ifihan | 1024×600 | |
12 | Iboju ifihan | 5-inch iboju ifọwọkan, ipinnu 1024×600 | |
13 | Oluwari | Ifihan OLED ti o ga, 1024 x 600 awọn piksẹli | |
14 | Ipo ifihan | Ipo infurarẹẹdi. Ipo igbelaruge gaasi. Ipo wiwọn otutu infurarẹẹdi. Ipo ina han. Aworan-ni-aworan mode. Ipo idapọ; | |
15 | Atunṣe aworan | Imọlẹ aifọwọyi ati afọwọṣe ati atunṣe itansan | |
16 | Paleti | 10 orisi + 1 olumulo-telẹ | |
17 | Kamẹra oni nọmba | Aaye wiwo jẹ ibamu pẹlu lẹnsi infurarẹẹdi | |
18 | Awọn imọlẹ LED | Bẹẹni | |
19 | Iwọn iwọn otutu ati itupalẹ | Iwọn wiwọn iwọn otutu | 1 ohun elo:-20 - 150 ° C 2 ohun elo:100 - 650 ° C |
20 | Yiye | ± 3 ℃or ± 3%(Mu iye ti o tobi julọ, iwọn otutu ibaramu jẹ 15 ° C si 35 ° C) | |
21 | Iwọn iwọn otutu aaye aarin | Bẹẹni | |
22 | Iwọn iwọn otutu aaye gbigbe | Ṣe atilẹyin awọn aaye 10 | |
23 | Iwọn iwọn otutu agbegbe gbigbe | Ṣe atilẹyin awọn iyika 10 ati awọn onigun mẹrin 10 | |
24 | Iwọn iwọn otutu laini gbigbe | Ṣe atilẹyin awọn ila 10 | |
25 | Ga ati kekere otutu ojuami aye | Ṣe atilẹyin iboju kikun giga ati ipo ipo iwọn otutu kekere ati ipo ipo iwọn otutu giga ati kekere ni agbegbe | |
26 | Tito wiwọn | Ko si wiwọn, aaye aarin, aaye iwọn otutu ti o pọju, aaye iwọn otutu ti o kere ju, iwọn otutu apapọ | |
27 | Itaniji iwọn otutu | Awọn itaniji awọ (awọn ila isothermal): loke/isalẹ awọn ipele iwọn otutu pato, laarin awọn ipele iwọn otutu pàtó. Awọn itaniji iṣẹ wiwọn: Awọn itaniji ti n gbọ (loke/isalẹ/laarin awọn ipele iwọn otutu ti a ti sọ tẹlẹ). | |
28 | Atunse iye iwọn | Emissivity (0.01 si 1.0 yiyan), iwọn otutu afihan, ọriniinitutu ibatan, iwọn otutu oju aye, ijinna ibi-afẹde, isanpada ir window ita | |
29 | Ibi ipamọ ọjọ | Alabọde ipamọ | Kaadi iranti TF yiyọ kuro |
30 | Ya awọn aworan nigbagbogbo | 3 iṣẹju-aaya si awọn wakati 24 | |
31 | Abinibi kikun radiometric image onínọmbà | Awọn aworan igbona radiometric ti o fipamọ le jẹ satunkọ ati itupalẹ lori kamẹra | |
32 | Aworan faili kika | Awọn aworan JPEG boṣewa, pẹlu awọn fọto oni-nọmba ati data radiometric ni kikun | |
33 | Igbasilẹ fidio infurarẹẹdi Radiometric | Gbigbasilẹ fidio itankalẹ gidi-akoko, * .aise faili ti wa ni ipamọ ni kaadi TF | |
34 | Igbasilẹ fidio infurarẹẹdi ti kii ṣe itanna | * .avi fidio faili, fi si TF kaadi | |
35 | Aworan alaye | Ohùn: 60 aaya, ti o fipamọ pẹlu aworan Ọrọ: Ṣafikun tabili, yan laarin awọn awoṣe asọye | |
36 | Wiwo ifihan latọna jijin | Wo awọn ṣiṣan fidio ni akoko gidi lori Wi-Fi kanasopọ. Sopọ si ifihan nipasẹ HDMI wiwo-giga ni wiwo; | |
37 | Latọna isẹ iṣakoso | Sopọ si iṣakoso sọfitiwia igbẹhin nipasẹ Wi-Fi; | |
38 | Ibaraẹnisọrọ ati awọn pẹẹpẹẹpẹ | ni wiwo | USB 2.0, Wi-Fi, HDMI |
39 | WIFI | Bẹẹni | |
40 | Ohun | Gbohungbohun ati agbọrọsọ fun asọye ohun aworan ati gbigbasilẹ fidio | |
41 | ijuboluwole lesa | Bẹẹni | |
42 | GPS | Ṣe atilẹyin ipo satẹlaiti, alaye ipo le wa ni fipamọ ni aworan naa | |
43 | Ibi ti ina elekitiriki ti nwa | Iru batiri | Batiri itanna litiumu gbigba agbara |
44 | Batiri foliteji | 7.4v | |
45 | Ilọsiwaju akoko iṣẹ | Ko kere ju wakati 4 ni iwọn otutu yara | |
46 | Ipese agbara ita | Ṣe atilẹyin ipese agbara dc12v ita | |
47 | Isakoso agbara | Tiipa aifọwọyi tabi pipa iboju aifọwọyi, akoko le yan lati rara, 5min, 10min, 30min | |
48 | Ayika aṣamubadọgba
| Awọn iwọn otutu ti nṣiṣẹ | -20-+ 50 ℃ |
49 | Iwọn otutu ipamọ | -40-+ 70 ℃ | |
55 | Awọn ohun-ini ti ara | Iwọn (laisi batiri) | ≤ 1.8 kg |
56 | Awọn iwọn (H*W*L) | ≤185 mm × 148 mm × 155 mm (pẹlu awọn lẹnsi boṣewa) | |
57 | Tripod òke mimọ | Iwọnwọn,1/4"-20 |