GDCR3200C Double Dimole Multifunctional Earth Resistance Tester ti wa ni Pataki ti apẹrẹ ati ti ṣelọpọ fun on-ojula wiwọn ti grounding resistance, ile resistivity, grounding foliteji, grounding laini jijo lọwọlọwọ, AC lọwọlọwọ ati DC resistance.Ohun elo naa gba imọ-ẹrọ iṣelọpọ oni-nọmba ti ilọsiwaju, pẹlu ọna 2-waya, ọna 3-waya, ọna 4-waya, ọna yiyan, ọna dimole meji ati awọn ọna wiwọn miiran;Ṣe agbewọle FFT (Fast Fourier Transform), imọ-ẹrọ AFC (Iṣakoso Igbohunsafẹfẹ Aifọwọyi Aifọwọyi), pẹlu agbara ikọlu alailẹgbẹ alailẹgbẹ ati ibaramu ayika, aitasera idanwo ti o ga, ti o rii daju pe konge giga, iduroṣinṣin giga ati igbẹkẹle giga fun wiwọn igba pipẹ. Apẹrẹ dimole lọwọlọwọ alaja nla, le ṣe pẹlu gbogbo iru awọn ibeere idanwo, o le wiwọn iye resistance grounding ti iwọn nla si isalẹ asiwaju, rọ wiwọn iye resistance grounding ti aaye ẹyọkan ati ilẹ grid ati gbogbo iru eto ipilẹ ilẹ eka, ko si iwulo lati ge asopọ eyikeyi igi ilẹ ti o jọra nigbati o ṣe iwọn eto ipilẹ ilẹ ti o jọra, ṣe imudara irọrun ti wiwọn, fun idanwo iṣẹ ṣiṣe ilẹ pese ojutu pipe.
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester jẹ ti ẹrọ ogun, dimole lọwọlọwọ (dimole meji), awọn okun idanwo, ọpa ilẹ iranlọwọ, sọfitiwia data ati awọn okun ibaraẹnisọrọ ati bẹbẹ lọ.Ifihan LCD nla ti ẹrọ agbalejo pẹlu ina ẹhin funfun ati itọkasi ayaworan igi ti o le rii ni kedere.Oluyẹwo naa ni iṣẹ ipamọ, iṣẹ aago, ati pe o tọju awọn ẹgbẹ 2000 laifọwọyi ti awọn esi idanwo ti o ni ọjọ ati akoko. Oluyẹwo pẹlu iṣẹ ibaraẹnisọrọ Bluetooth n ṣe atilẹyin eto Android.Lẹhin fifi sori ẹrọ ti APP, le ṣe idanwo tabi ka awọn igbasilẹ idanwo ni ebute alagbeka, mu iriri tuntun wa.Oluyẹwo n pese wiwo USB, ati pe data ti o fipamọ le ṣe gbejade si PC nipasẹ wiwo USB.Sọfitiwia ibaraẹnisọrọ le mọ awọn iṣẹ ti kika, ijumọsọrọ, fifipamọ, ijabọ ati titẹ data igbasilẹ itan.Ti a lo ni agbara, awọn ibaraẹnisọrọ, meteorology, awọn aaye epo, ikole, aabo monomono ati ohun elo itanna ile-iṣẹ.
●Apẹrẹ alailẹgbẹ ti ina Atọka Jack, itọkasi deede ti ipo Jack, yago fun aṣiṣe iṣẹ.
●Bọtini yiyan iṣẹ jia, ọpọlọpọ awọn ọna idanwo ti han, ṣiṣe iṣẹ naa rọrun ati iyara.
●Oluyẹwo naa ni iṣẹ ibaraẹnisọrọ Bluetooth ati atilẹyin eto Android.Awọn olumulo le lo ebute alagbeka lati ṣe idanwo iṣẹ tabi ka awọn abajade idanwo ti o ni ọjọ ati akoko ni irọrun pupọ.
●Ọran irinse gba apoti aabo ti ko ni omi, eyiti o lagbara, ailewu ati ti o tọ fun ikọlu-ija, egboogi-isubu ati mabomire (ipele aabo IP65), paapaa dara fun lilo ni awọn aaye ikole ita gbangba.
●Mita naa ti ni ipese pẹlu idii batiri litiumu gbigba agbara nla.Ati pẹlu USB ni wiwo lati po si data iṣẹ.
Awọn ipo ipilẹ & Awọn ipo iṣẹ
| Ipa Opoiye | Ipilẹ Ipò | Awọn ipo Ṣiṣẹ | Akiyesi |
| Ibaramu otutu | 23℃±1℃ | -10℃-40℃ | ---- |
| Ọriniinitutu ibaramu | 40% -60% | .80% | ---- |
| Ṣiṣẹ Foliteji | 7.8V± 0.1V | DC 7.8V ± 0.6V | ---- |
| Iranlọwọ Earth Resistance | .100Ω | .5kΩ | |
| kikọlu foliteji | Yẹ ki o yago fun | .20V | |
| kikọlu lọwọlọwọ | Yẹ ki o yago fun | .2A | |
| Ijinna elekitirode nigba idiwon R | a:5d | a:5d | |
| Electrode Ijinna nigba idiwon ρ | a:20h | a:20h |
Gbogbogbo sipesifikesonu
| Išẹ | Wiwọn resistance grounding, ile resistivity;Atako DC, foliteji ilẹ, alternating lọwọlọwọ, lọwọlọwọ jijo | |
| Ibi ti ina elekitiriki ti nwa | DC 7.4V 2600mAh batiri lithium gbigba agbara, o kun fun nipa 8.4V | |
| Imọlẹ ẹhin | Iboju backlight Iṣakoso, o dara fun awọn aaye baibai | |
| Ọna Idiwọn | DC resistance | DC resistance 2-waya ọna |
| DC resistance 4-waya ọna | ||
| Earth resistance | Earth resistance 2-waya ọna | |
| Earth resistance 3-waya ọna | ||
| Earth resistance 4-waya ọna | ||
| Ọna dimole kanṣoṣo ti ilẹ-aye ni ọna waya (ọna yiyan) | ||
| Ọna asopọ oni-waya 4 resistance ọkan (ọna yiyan) | ||
| Earth resistance double dimole ọna | ||
| Atako ile (ọna Wenner) | ||
| Aye lọwọlọwọ | Iwọn dimole lọwọlọwọ | |
| Foliteji Earth | Atunse apapọ | |
| Idanwo Voltage igbi | Sine igbi | |
| Igbeyewo Igbohunsafẹfẹ | 128Hz/111Hz/105Hz/94Hz(AFC) | |
| Idanwo kukuru-kukuru Lọwọlọwọ | Iye ti o ga julọ ti AC 250mA | |
| Ṣii-Circuit Idanwo Lọwọlọwọ | Iye ti o ga julọ ti AC40V | |
| Electrode Distance Range | 1m-100m | |
| Ipo ifihan | 4-oni nla LCD àpapọ, pẹlu iboju backlight | |
| Atọka Idiwọn | Lakoko wiwọn, Atọka filasi LED, ifihan kika kika LCD | |
| LCD fireemu Dimension | 128mm×75mm | |
| LCD àpapọ agbegbe | 124mm×67mm | |
| Irinse Dimension | 280mm(L) X 260mm(W) X 160mm(H) | |
| Iwọn CT | 223mm X 120mm X 39mm | |
| Idanwo Waya | Awọn okun onirin 4: ọkọọkan fun pupa 20m, dudu 20m, ofeefee 10m, ati awọ ewe 10m | |
| Okun Idanwo Rọrun | 2 onirin: kọọkan fun pupa 1.6m ati dudu 1.6m | |
| Iranlọwọ Grounding Rod | 4PCS: Φ10mm X150mm | |
| Dimole lọwọlọwọ | 2PCS: 1 buluu-dudu plug ati 1 pupa-dudu plug | |
| Dimole Caliber | Φ70mm | |
| Dimole Lead Waya | 2m | |
| Oṣuwọn Iwọn | AC lọwọlọwọ: nipa awọn akoko 2 / iṣẹju-aaya | |
| Foliteji Earth: bii awọn akoko 2 / iṣẹju-aaya | ||
| Idaabobo ile: nipa 7 aaya / akoko | ||
| Awọn akoko wiwọn | Ju awọn akoko 5000 lọ (idanwo kukuru-kukuru, akoko aarin yẹ ki o jẹ o kere ju awọn aaya 30) | |
| Laini Foliteji | Wiwọn ni isalẹ AC 600V | |
| Ibaraẹnisọrọ Interface | Module Bluetooth, wiwo USB, data ibi ipamọ le ṣe igbasilẹ si kọnputa, fipamọ tabi tẹjade. | |
| Waya ibaraẹnisọrọ | Okun ibaraẹnisọrọ USB x1pcs, pẹlu ipari 1.5m | |
| Idaduro data | Data idaduro iṣẹ: "HOLD" àpapọ aami | |
| Ibi ipamọ data | Awọn ẹgbẹ 2000, Atọka ibi ipamọ “MEM”, “FULL” aami ibi ipamọ iboju filasi ti kun | |
| Wiwọle Data | Iṣẹ kika data: "KA" ifihan aami | |
| Aponsedanu Ifihan | Kọja iwọn iwọn iṣẹ aponsedanu: "OL" ifihan | |
| Atọka lọwọlọwọ kekere ti dimole lọwọlọwọ | Wiwọn pẹlu ọna yiyan tabi dimole ilọpo meji, ifihan agbara lọwọlọwọ ti o gba nipasẹ CT2 kere ju 0.5mA, yoo han “”, ati pe o yẹ ki o ṣayẹwo itọsọna didi ti dimole lọwọlọwọ CT2 | |
| Idanwo kikọlu | Idanimọ aifọwọyi ti awọn ifihan agbara kikọlu, itọkasi aami “NOISE” nigbati foliteji kikọlu ba ga ju 5V | |
| Idanwo Grounding Iranlọwọ | Pẹlu iṣẹ idanwo idena ilẹ iranlọwọ, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) | |
| Iṣẹ-ṣiṣe itaniji | Iwọn wiwọn kọja iye eto itaniji, yoo ṣe ohun itaniji “Toot-toot-toot”. | |
| Batiri Foliteji | Lakoko ti foliteji batiri dinku si ayika 7.2V± 0.1V, yoo han aami foliteji batiri kekere, ati olurannileti lati rọpo batiri naa | |
| Tiipa aifọwọyi | Tiipa ni aifọwọyi lẹhin iṣẹju 15 ti ina | |
| Ṣiṣẹ Lọwọlọwọ | Imọlẹ ẹhin: 25mA Max (agbara agbara afẹyinti nikan) | |
| Imurasilẹ: 25mA Max (Imọlẹ ẹhin wa ni pipa lẹhin titan) | ||
| Iwọn: 150mA ti o pọju (Tiipa afẹyinti) | ||
| Iwọn | Idanwo: 2290g | |
| Dimole lọwọlọwọ: 1100g (2pcs) | ||
| Lapapọ iwuwo: 6800g (pẹlu gbogbo awọn ẹya ẹrọ) | ||
| Ṣiṣẹ otutu & Ọriniinitutu | -10℃-40℃, ni isalẹ 80% rh | |
| Ibi ipamọ otutu & ọriniinitutu | -20 ℃-60 ℃, ni isalẹ 70% rh | |
| Ipele Idaabobo | IP65 (pa apoti naa) | |
| Apọju Idaabobo | Wiwọn resistance aiye: laarin kọọkan awọn atọkun ti C (H) -E,P (S) -ES, AC 280V / 3 aaya | |
| Idabobo Resistance | Ju 20MΩ (laarin iyika ati ikarahun ita jẹ 500V) | |
| Ifarada Foliteji | AC 3700V/rms.(Laarin iyika ati ikarahun ita) | |
| Itanna Awọn ẹya ara ẹrọ | IEC61326(EMC) | |
| Iru Idaabobo | IEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Idoti 2); IEC61010-031; IEC61557-1 (Itako Aye); IEC61557-5 (Atako ile); JJG 366-2004 (Mita resistance ti ilẹ) JJG 1054-2009 (mita idena ilẹ dimole) | |